Numerical Investigation of the Thermal–Hydraulic Performance of a Double‐Pipe Heat Exchanger With Porous Inserts

S. B. Anjappa, Shivaranjini, K. Ganesh, Mohit Kumar Agrawal, Umesh Gupta, Prabhukumar Sellamuthu

Heat Transfer · 22.11.2026

DOI: 10.1002/htj.70426 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Heat Transfer, online erschienen am 22.11.2026. Verfasst von S. B. Anjappa und 5 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Double‐pipe heat exchangers (DPHEs) are widely used because of their simple design, operational reliability, and effective heat‐transfer capability. This study presents a three‐dimensional computational fluid dynamics (CFD) analysis of a counterflow DPHE fitted with interrupted and staggered (St.) segmented copper‐foam inserts in the annular region. Numerical simulations were performed using ANSYS Fluent, employing the Darcy–Brinkman–Forchheimer porous media model coupled with the local thermal nonequilibrium energy model to accurately predict the fluid flow and heat transfer within the porous structure. Ten porous configurations, comprising interrupted and staggered arrangements with different segment arrangements and configurations, were evaluated over a Reynolds number range of 205–1435. The thermo‐hydraulic performance was assessed using the Nusselt number, friction factor, and thermal performance factor (TPF). Compared with the smooth annulus, the interrupted configurations increased the average Nusselt number by 269.3%–293.7%, whereas the staggered configurations increased it by 308.6%–389.1%. These improvements were accompanied by an increase in the friction factor of 196.1%–213.5% and 259.6%–372.9%, respectively. Despite the additional pressure loss, all configurations produced TPF values greater than unity, ranging from 2.58 to 2.71 for interrupted arrangements and 2.70 to 3.00 for staggered arrangements, confirming an overall improvement in the thermo‐hydraulic performance. Although the optimum configuration varied with Re , the St.‐3–11 arrangement delivered the best overall performance across the investigated range, whereas St.‐3–5 achieved the highest TPF at Re = 205. These results demonstrate that segmented, staggered copper‐foam inserts provide an effective passive enhancement technique for compact, energy‐efficient DPHEs used in thermal energy storage, waste heat recovery, heating, ventilation, and air conditioning (HVAC) systems, and the process industry.

Zitieren

APA

Anjappa, S. B., Shivaranjini, Ganesh, K., Agrawal, M. K., Gupta, U., & Sellamuthu, P. (2026). Numerical Investigation of the Thermal–Hydraulic Performance of a Double‐Pipe Heat Exchanger With Porous Inserts. Heat Transfer. https://doi.org/10.1002/htj.70426

Vancouver

Anjappa SB, Shivaranjini, Ganesh K, Agrawal MK, Gupta U, Sellamuthu P. Numerical Investigation of the Thermal–Hydraulic Performance of a Double‐Pipe Heat Exchanger With Porous Inserts. Heat Transfer. 2026. doi:10.1002/htj.70426

BibTeX
@article{Anjappa2026,
  author = {Anjappa, S. B. and Shivaranjini and Ganesh, K. and Agrawal, Mohit Kumar and Gupta, Umesh and Sellamuthu, Prabhukumar},
  title = {Numerical Investigation of the Thermal–Hydraulic Performance of a Double‐Pipe Heat Exchanger With Porous Inserts},
  journal = {Heat Transfer},
  year = {2026},
  doi = {10.1002/htj.70426}
}
Kostenlos starten →