EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Microbial Contamination of Radiology Equipment: A Descriptive Study in Ghana

Seth Kwadjo Angmorterh iD, John Gameli Deku iD, Emmanuel Akyea-Mensah, Riaan Van de Venter iD, Hubert Amu, Sonia Aboagye iD, Patience Nyamekye Agyemang, Nathaniel Awentiirin Angaag, Jevas Omweri Kenyanya, Kafui Kossi Kekessie, Benjamin Klugah-Brown iD

Health Science Reports · 2026-10 · 9 (10)

DOI: 10.1002/hsr2.73326 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Health Science Reports, online erschienen am 30.09.2026. Verfasst von Seth Kwadjo Angmorterh und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging, School of Allied Health Sciences University of Health and Allied Sciences Ho Ghana. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Aims Nosocomial infections continue to impose significant clinical and economic burdens on patients and healthcare systems worldwide. Radiology equipment, accessories, and work surfaces can become contaminated with healthcare‐associated pathogens due to frequent handling by healthcare personnel and patients. This study investigated microbial contamination on commonly used radiology equipment and surfaces at a major hospital in Ghana.

Methods

This descriptive microbiological study involved weekly swabbing of 10 radiology equipment/accessories and surfaces using sterile nylon swabs over a 4‐week period. Swab samples were transferred into bijoux bottles containing peptone broth to enhance microbial growth. For bacterial isolation, samples were inoculated onto MacConkey and Blood Agar plates and incubated appropriately. Bacterial isolates were identified based on colonial morphology, Gram staining, and biochemical reactions. Fungal cultures were performed using Sabouraud Dextrose Agar and incubated at 28°C for 7 days. Fungal isolates were identified using colonial morphology, tease mount preparation, and lactophenol cotton blue staining.

Results

Microbial contamination was detected in 35 (87.5%) of the 40 samples analyzed. Identified bacterial isolates included coagulase‐negative Staphylococci, Klebsiella pneumoniae, Bacillus species, and Staphylococcus aureus . These organisms were isolated from the 35/43 cm cassette, x‐ray tube head handle, horizontal bucky surface, and erect bucky surface. The highest bacterial colony count recorded was 1.2 × 10 6 CFU/cm 2 . The 35/43 cm x‐ray cassette demonstrated the highest level of contamination, accounting for 4 of the 9 bacterial isolates identified. Fungal isolates, including Neurospora species and Fusarium solani , were also detected.

Conclusion

Radiology equipment and surfaces harbored potentially pathogenic bacterial and fungal organisms, indicating their capacity to act as environmental reservoirs within radiology departments. The detection of both bacterial and fungal species on frequently touched radiology items highlights the need for strict adherence to infection prevention and control protocols to enhance the safety of both patients and healthcare professionals.

Schlagwörter

Stichwörter der Autor:innen

Ghanahospital‐acquired infectionsinfection prevention and controlnosocomial pathogenspatient safetyradiographyradiology

Autor:innen und Institutionen

  • Department of Medical Imaging, School of Allied Health Sciences University of Health and Allied Sciences Ho Ghana.
  • Department of Medical Laboratory Sciences, School of Allied Health Sciences University of Health and Allied Sciences Ho Ghana.
  • Department of Radiography, School of Clinical Care and Medicinal Sciences, Faculty of Health Sciences Nelson Mandela University Gqeberha South Africa.
  • Department of Population and Behavioural Sciences, Fred N. Binka School of Public Health University of Health and Allied Sciences Hohoe Ghana.
  • Department of Speech, Language & Hearing Sciences, School of Allied Health Sciences University of Health and Allied Sciences Ho Ghana.
  • The Clinical Hospital of Chengdu Brain Science Institute, MOE Key Laboratory for Neuroinformation, School of Life Science and Technology University of Electronic Science and Technology of China Chengdu Sichuan China.

ORCID-Profile: Seth Kwadjo Angmorterh, John Gameli Deku, Riaan Van de Venter, Sonia Aboagye, Benjamin Klugah-Brown

Zitieren

APA

Angmorterh, S. K., Deku, J. G., Akyea-Mensah, E., de Venter, R. V., Amu, H., Aboagye, S., Agyemang, P. N., Angaag, N. A., Kenyanya, J. O., Kekessie, K. K., & Klugah-Brown, B. (2026). Microbial Contamination of Radiology Equipment: A Descriptive Study in Ghana. Health Science Reports, 9(10). https://doi.org/10.1002/hsr2.73326

Vancouver

Angmorterh SK, Deku JG, Akyea-Mensah E, de Venter RV, Amu H, Aboagye S, et al. Microbial Contamination of Radiology Equipment: A Descriptive Study in Ghana. Health Science Reports. 2026;9(10). doi:10.1002/hsr2.73326

BibTeX
@article{Angmorterh2026,
  author = {Angmorterh, Seth Kwadjo and Deku, John Gameli and Akyea-Mensah, Emmanuel and de Venter, Riaan Van and Amu, Hubert and Aboagye, Sonia and Agyemang, Patience Nyamekye and Angaag, Nathaniel Awentiirin and Kenyanya, Jevas Omweri and Kekessie, Kafui Kossi and Klugah-Brown, Benjamin},
  title = {Microbial Contamination of Radiology Equipment: A Descriptive Study in Ghana},
  journal = {Health Science Reports},
  year = {2026},
  volume = {9},
  number = {10},
  doi = {10.1002/hsr2.73326}
}
Kostenlos starten →