EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Assessment of hematology laboratory performance in the total testing process using quality indicators and sigma metrics in the northwest of Ethiopia: A cross‐sectional study

Dereje Mengesha Berta iD, Mekonnen Grima, Mulugeta Melku iD, Tiruneh Adane, Elias Chane, Bisrat Birke Teketelew, Aregawi Yalew

Health Science Reports · 2024-01 · 7 (1)

DOI: 10.1002/hsr2.1833 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Health Science Reports, online erschienen am 22.01.2024. Verfasst von Dereje Mengesha Berta und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hematology and Immunohematology University of Gondar Gondar Ethiopia. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: College of Medicine and Health Sciences, University of Gondar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Aims Assuring laboratory quality by minimizing the magnitude of errors is essential. Therefore, this study aimed to assess hematology laboratory performance in the total testing process using quality indicators and sigma metrics.

Methods

A cross‐sectional study was conducted from April to June 2022. The study included a total of 13,546 samples. Data on included variables were collected using a checklist. Descriptive statistics were used to present the overall distribution of errors. Binary logistic regression models were applied. Furthermore, using a Sigma scale, the percentage of errors was converted to defects per million opportunities to assess laboratory performance. Finally, the defect per million opportunities was converted to a sigma value using a sigma calculator.

Results

Of the 13,546 samples and corresponding requests, the overall error rate was 123,296/474,234 (26%): 93,412/47,234 (19.7%) pre‐analytical, 2364/474,234 (0.5%) analytical, and 27,520/474,234 (5.8%) post‐analytical. Of the overall errors, 93,412/123,296 (75.8%), 2364/123,296 (1.9%), and 27,520/123,296 (22.3%) were pre‐analytical, analytical, and post‐analytical errors, respectively. The overall sigma value of the laboratory was 2.2. The sigma values of the pre‐analytical, analytical, and post‐analytical phases were 2.4, 4.1, and 3.1, respectively. The sample from the inpatient department and collected without adherence to the standard operating procedures (SOPs) had a significantly higher ( p < 0.05) rejection rate as compared to the outpatient department and collected with adherence to SOPs, respectively. In addition, an association between prolonged turnaround times and manual recording, inpatient departments, and morning work shifts was observed.

Conclusion

The current study found that the overall performance of the laboratory was very poor (less than three sigma). Therefore, the hospital leadership should change the manual system of ordering tests and release of results to a computerized system and give need‐based training for all professionals involved in hematology laboratory sample collection and processing.

Schlagwörter

Stichwörter der Autor:innen

hematologylaboratoryquality indicatorssigma metricstesting process

Autor:innen und Institutionen

  • Department of Hematology and Immunohematology University of Gondar Gondar Ethiopia.
  • Department of Quality Assurance and Laboratory Management, School of Biomedical and Laboratory Sciences, College of Medicine and Health Sciences University of Gondar Gondar Ethiopia.
  • Flinders University Adelaide South Australia Australia.
  • Department of Clinical Chemistry, School of Biomedical and Laboratory Sciences University of Gondar Gondar Ethiopia.

ORCID-Profile: Dereje Mengesha Berta, Mulugeta Melku

Förderung

  • College of Medicine and Health Sciences, University of Gondar

Zitieren

APA

Berta, D. M., Grima, M., Melku, M., Adane, T., Chane, E., Teketelew, B. B., & Yalew, A. (2024). Assessment of hematology laboratory performance in the total testing process using quality indicators and sigma metrics in the northwest of Ethiopia: A cross‐sectional study. Health Science Reports, 7(1). https://doi.org/10.1002/hsr2.1833

Vancouver

Berta DM, Grima M, Melku M, Adane T, Chane E, Teketelew BB, et al. Assessment of hematology laboratory performance in the total testing process using quality indicators and sigma metrics in the northwest of Ethiopia: A cross‐sectional study. Health Science Reports. 2024;7(1). doi:10.1002/hsr2.1833

BibTeX
@article{Berta2024,
  author = {Berta, Dereje Mengesha and Grima, Mekonnen and Melku, Mulugeta and Adane, Tiruneh and Chane, Elias and Teketelew, Bisrat Birke and Yalew, Aregawi},
  title = {Assessment of hematology laboratory performance in the total testing process using quality indicators and sigma metrics in the northwest of Ethiopia: A cross‐sectional study},
  journal = {Health Science Reports},
  year = {2024},
  volume = {7},
  number = {1},
  doi = {10.1002/hsr2.1833}
}
Kostenlos starten →