EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Computer‐Aided Diagnosis in the Evaluation of Thyroid Nodules: A Study of Intra‐ And Inter‐Rater Reliability and Agreement

Leonardo de Souza Piber iD, Luis Carlos Uta Nakano iD, Carolina Dutra Queiroz Flumignan iD, Ronald Luiz Gomes Flumignan iD

Head & Neck · 2026-09 · 48 (9) · 2456-2469

DOI: 10.1002/hed.70264 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Head & Neck, online erschienen am 06.04.2026. Verfasst von Leonardo de Souza Piber und 3 weiteren Autor:innen. Beteiligte Einrichtung: Evidence-Based Health, Universidade Federal de São Paulo, São Paulo, Brazil. Hauptthemen laut MEDLINE: Thyroid Nodule, Diagnosis, Computer-Assisted. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the intra‐ and inter‐rater reliability of a computer‐aided diagnosis system applied to thyroid nodule assessment.

Methods

This prospective, single‐center study included 150 thyroid nodules evaluated by two physicians at two time points, 90 days apart. Analyses were performed using the AmCAD‐UT system, focusing on morphological features and ACR TI‐RADS classification. Cohen's kappa coefficient and percentage agreement were used to assess reliability.

Results

Intra‐rater reliability ranged from moderate to almost perfect, with kappa values from 0.49 (95% CI: 0.31–0.66) to 0.98 (95% CI: 0.96–1.00), and agreement rates from 81.3% to 99.3%. Rater 2 demonstrated higher reproducibility across most variables, particularly for “texture” ( k = 0.98), “margin” ( k = 0.90), “composition” ( k = 0.93), and “taller‐than‐wide” ( k = 0.92). Inter‐rater agreement was more variable, with kappa values ranging from 0.43 (95% CI: 0.23–0.62) to 0.96 (95% CI: 0.89–1.00), and agreement percentages from 78.0% to 99.3%. The lowest inter‐rater reproducibility was observed for “shape”.

Conclusion

The computer‐aided diagnosis system demonstrated predominantly moderate to almost perfect intra‐rater reliability and moderate to strong inter‐rater agreement across most evaluated features. The highest reproducibility was observed for “taller‐than‐wide,” “texture,” and “composition,” whereas “shape” consistently showed lower agreement. These findings support the system's role as a reliable adjunct for standardizing thyroid nodule assessment, although its performance remains partially influenced by operational factors and warrants further multicenter validation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Thyroid NoduleDiagnosis, Computer-AssistedHumansReproducibility of ResultsObserver VariationProspective StudiesFemaleMaleMiddle AgedAdultBiopsy, Fine-Needle

Stichwörter der Autor:innen

computer‐aided diagnosisinter‐rater agreementreliabilitythyroid noduleultrasonography

Autor:innen und Institutionen

  • Evidence-Based Health, Universidade Federal de São Paulo, São Paulo, Brazil.
  • Division of Vascular and Endovascular Surgery, Department of Surgery, Universidade Federal de São Paulo, São Paulo, Brazil.
  • Discipline of Vascular and Endovascular Surgery, Centro Universitário São Camilo, São Paulo, Brazil.

ORCID-Profile: Leonardo de Souza Piber, Luis Carlos Uta Nakano, Carolina Dutra Queiroz Flumignan, Ronald Luiz Gomes Flumignan

Zitieren

APA

Piber, L. S., Nakano, L. C. U., Flumignan, C. D. Q., & Flumignan, R. L. G. (2026). Computer‐Aided Diagnosis in the Evaluation of Thyroid Nodules: A Study of Intra‐ And Inter‐Rater Reliability and Agreement. Head & Neck, 48(9), 2456-2469. https://doi.org/10.1002/hed.70264

Vancouver

Piber LS, Nakano LCU, Flumignan CDQ, Flumignan RLG. Computer‐Aided Diagnosis in the Evaluation of Thyroid Nodules: A Study of Intra‐ And Inter‐Rater Reliability and Agreement. Head & Neck. 2026;48(9):2456-2469. doi:10.1002/hed.70264

BibTeX
@article{Piber2026,
  author = {Piber, Leonardo de Souza and Nakano, Luis Carlos Uta and Flumignan, Carolina Dutra Queiroz and Flumignan, Ronald Luiz Gomes},
  title = {Computer‐Aided Diagnosis in the Evaluation of Thyroid Nodules: A Study of Intra‐ And Inter‐Rater Reliability and Agreement},
  journal = {Head & Neck},
  year = {2026},
  volume = {48},
  number = {9},
  pages = {2456--2469},
  doi = {10.1002/hed.70264}
}
Kostenlos starten →