EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Surgeon Review of 4D CT for Identification of Parathyroid Adenomas

Keerthi E Kurian iD, Osama Hamdi, Zoe A Roecker, Simone A Barker, Andrew Strumpf, Jonathan C Garneau iD, David C Shonka iD

Head & Neck · 2025

DOI: 10.1002/hed.27970 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Head & Neck, 2025. Verfasst von Keerthi E Kurian und 6 weiteren Autor:innen. Beteiligte Einrichtung: California Northstate University College of Medicine, Elk Grove, California, USA. Hauptthemen laut MEDLINE: Parathyroid Neoplasms, Four-Dimensional Computed Tomography, Adenoma. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Preoperative localization of parathyroid adenomas aids surgical planning for patients with hyperparathyroidism. This study explores the diagnostic accuracy of surgeon‐reviewed 4D computed tomography (4D CT) scans for localization of parathyroid adenomas.

Methods

A retrospective review of 95 patients with hyperparathyroidism who underwent parathyroidectomy at a tertiary care center was performed. The sensitivity, specificity, positive and negative predictive values, accuracy of identifying abnormal glands by surgeon, and interrater reliability between two head and neck surgeons was assessed.

Results

The sensitivity of surgeon localization of all glands was 71% (95% CI, 63%–78%), improving to 76% when combined with radiology reads. The specificity was 98% (95% CI, 95%–99%), the positive predictive value was 95% (95% CI, 90%–99%), and the negative predictive value was 84% (95% CI, 79%–88%) for all abnormal glands. Interrater reliability between surgeons was κ = 0.771.

Conclusions

The diagnostic accuracy of surgeon localization of abnormal glands on the 4D CT scan was substantial. Improvement with radiology report integration highlights the benefits of multidisciplinary collaboration. Interrater reliability between two fellowship‐trained surgeons was moderate. These findings support the importance of surgeons developing proficiency in reading 4D CT scans to engage in interdisciplinary communication and improve patient outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Parathyroid NeoplasmsFour-Dimensional Computed TomographyAdenomaHumansRetrospective StudiesFemaleMaleMiddle AgedParathyroidectomyAdultReproducibility of ResultsAgedSensitivity and SpecificityPredictive Value of TestsObserver Variation

Stichwörter der Autor:innen

4D CThyperparathyroidismparathyroid adenomapreoperative imagingsurgical planning

Autor:innen und Institutionen

  • California Northstate University College of Medicine, Elk Grove, California, USA.
  • Department of Otolaryngology-Head and Neck Surgery, University of Virginia, Charlottesville, Virginia, USA.

ORCID-Profile: Keerthi E Kurian, Jonathan C Garneau, David C Shonka

Zitieren

APA

Kurian, K. E., Hamdi, O., Roecker, Z. A., Barker, S. A., Strumpf, A., Garneau, J. C., & Shonka, D. C. (2025). Surgeon Review of 4D CT for Identification of Parathyroid Adenomas. Head & Neck. https://doi.org/10.1002/hed.27970

Vancouver

Kurian KE, Hamdi O, Roecker ZA, Barker SA, Strumpf A, Garneau JC, et al. Surgeon Review of 4D CT for Identification of Parathyroid Adenomas. Head & Neck. 2025. doi:10.1002/hed.27970

BibTeX
@article{Kurian2025,
  author = {Kurian, Keerthi E and Hamdi, Osama and Roecker, Zoe A and Barker, Simone A and Strumpf, Andrew and Garneau, Jonathan C and Shonka, David C},
  title = {Surgeon Review of 4D CT for Identification of Parathyroid Adenomas},
  journal = {Head & Neck},
  year = {2025},
  doi = {10.1002/hed.27970}
}
Kostenlos starten →