EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Exploring the Sensitivity Limits of Neuronal Current Imaging With MRI and MEG in the Human Brain

Milena Capiglioni iD, Davide Tabarelli iD, Stefano Tambalo iD, Federico Turco iD, Roland Wiest iD, Jorge Jovicich iD

Human Brain Mapping · 2026-08 · 47 (11)

DOI: 10.1002/hbm.70624 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Human Brain Mapping, online erschienen am 07.08.2026. Verfasst von Milena Capiglioni und 5 weiteren Autor:innen. Beteiligte Einrichtung: Support Center for Advanced Neuroimaging (SCAN), Inselspital, Institute for Diagnostic and Interventional Neuroradiology, Bern, Bern, Switzerland. Hauptthemen laut MEDLINE: Magnetoencephalography, Magnetic Resonance Imaging, Brain Mapping, Brain. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: International Society for Magnetic Resonance in Medicine, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Conventional BOLD‐fMRI relies on hemodynamic responses that are temporally and spatially indirect markers of neural activity. Developing alternative contrasts, sensitive to neuroelectrical phenomena, is a critical challenge in brain imaging. Spin‐lock (SL) fMRI has shown promise in phantom studies for detecting magnetic field changes associated with neuronal activity, but its in‐vivo sensitivity and practicality remain unclear. This study evaluated whether SL contrast can effectively detect and localize human neuronal activation, benchmarked against complementary functional modalities, magnetoencephalography (MEG) and 3T BOLD‐fMRI, to assess the sensitivity of MR‐based neuronal current imaging. Thirteen healthy young volunteers underwent SL‐based imaging during 8 Hz visual stimulation, along with BOLD and MEG acquisitions. Subjects viewed quadrant‐checkerboard stimuli to elicit localized cortical responses. Two balanced SL contrast mechanisms, rotary excitation (REX) and stimulus‐induced rotary saturation (SIRS), were employed. Postprocessing targeted stimulus‐locked signal fluctuations using a regression‐filtering‐rectification strategy. Phantom experiments tested sensitivity and analysis pipeline performance. MEG revealed robust stimulus‐locked responses in the occipital cortex, with estimated local magnetic field amplitudes of ~0.07 nT. Conventional BOLD‐fMRI confirmed reliable hemodynamic activation. In contrast, neither balanced REX nor balanced SIRS produced consistent stimulus‐related activation in vivo. Phantom experiments subsequently yielded detection thresholds of 0.2 nT for REX and 0.6 nT for SIRS, exceeding the MEG‐estimated physiological field amplitudes. Under the present experimental conditions, the tested spin‐lock fMRI implementations did not achieve sufficient sensitivity for reliable in vivo detection of neuronal magnetic fields at 3T. Phantom and MEG‐based estimates indicate that physiological field amplitudes in the visual cortex lie below current detection limits. These findings establish quantitative constraints on direct neuronal current imaging with MRI and provide a benchmark for future methodological developments aimed at bridging electrophysiology and functional MRI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MagnetoencephalographyMagnetic Resonance ImagingBrain MappingBrainHumansAdultMaleFemaleYoung AdultPhotic StimulationPhantoms, Imaging

Stichwörter der Autor:innen

MEGmultimodal imagingneuroelectrical oscillationsnon‐BOLD fMRIspin‐lock fMRI

Autor:innen und Institutionen

  • Support Center for Advanced Neuroimaging (SCAN), Inselspital, Institute for Diagnostic and Interventional Neuroradiology, Bern, Bern, Switzerland.
  • High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.
  • Center for Mind and Brain Sciences (CIMeC), University of Trento, Rovereto, Italy.
  • Department of Physics, University of Trento, Trento, Italy.
  • Trento Institute for Fundamental Physics and Applications (TIFPA-INFN), University of Trento, Trento, Italy.
  • Department of Physics, University of Torino, Torino, Italy.

ORCID-Profile: Milena Capiglioni, Davide Tabarelli, Stefano Tambalo, Federico Turco, Roland Wiest, Jorge Jovicich

Förderung

  • International Society for Magnetic Resonance in Medicine
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung

Zitieren

APA

Capiglioni, M., Tabarelli, D., Tambalo, S., Turco, F., Wiest, R., & Jovicich, J. (2026). Exploring the Sensitivity Limits of Neuronal Current Imaging With MRI and MEG in the Human Brain. Human Brain Mapping, 47(11). https://doi.org/10.1002/hbm.70624

Vancouver

Capiglioni M, Tabarelli D, Tambalo S, Turco F, Wiest R, Jovicich J. Exploring the Sensitivity Limits of Neuronal Current Imaging With MRI and MEG in the Human Brain. Human Brain Mapping. 2026;47(11). doi:10.1002/hbm.70624

BibTeX
@article{Capiglioni2026,
  author = {Capiglioni, Milena and Tabarelli, Davide and Tambalo, Stefano and Turco, Federico and Wiest, Roland and Jovicich, Jorge},
  title = {Exploring the Sensitivity Limits of Neuronal Current Imaging With MRI and MEG in the Human Brain},
  journal = {Human Brain Mapping},
  year = {2026},
  volume = {47},
  number = {11},
  doi = {10.1002/hbm.70624}
}
Kostenlos starten →