EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Standardizing TMS Intensity Across Different Coils Using Individualized Electric Field Modeling

Evgenii Kim iD, Mohammad Daneshzand, Keren Zhu iD, Danyal Fareed Bhutto iD, Teresa Jacobson Kimberley iD, Dylan Edwards, Netri Pajankar iD, Parker Kotlarz iD, Tommi Raij, Sergey N Makaroff iD, Aapo Nummenmaa

Human Brain Mapping · 01.06.2026 · 47 (8)

DOI: 10.1002/hbm.70550 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Human Brain Mapping, online erschienen am 30.05.2026. Verfasst von Evgenii Kim und 10 weiteren Autor:innen. Beteiligte Einrichtung: Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Transcranial Magnetic Stimulation, Electromagnetic Fields, Motor Cortex. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIH HHS, NIMH NIH HHS, NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantitative measures for Transcranial Magnetic Stimulation (TMS) intensity are needed to ensure safe and consistent application in therapeutic and research settings. However, resting motor thresholds (rMTs), commonly used to determine stimulation intensity, depend on the coil used. Unless motor mapping and treatment coils are identical, re‐thresholding is necessary, increasing patient discomfort and potentially introducing variability across studies. These considerations raise an unresolved fundamental question: does individual rMT reflect a consistent cortical electric field (E‐field) magnitude independent of coil geometry? We tested the hypothesis that rMT corresponds to a coil‐invariant cortical E‐field magnitude and evaluated a computational method for predicting stimulator output across different coils using a reference rMT. Thirteen healthy, right‐handed participants were recruited; ten were included in the primary analysis. Participants underwent TMS with two figure‐of‐eight coils of different sizes. E‐field distributions were simulated using a fast multipole boundary element method, in free space and within personalized MRI‐based head models. rMT prediction accuracy was compared between a detailed five‐layer and a simplified three‐layer head model, and both were evaluated against direct rMT scaling using the reference coil. The personalized E‐field‐based approach significantly improved rMT prediction accuracy over direct scaling ( p < 0.001). The root‐mean‐square error (RMSE) was 1.26% and 1.32% of maximum stimulator output (MSO) for detailed and simplified models, versus 6.1% MSO for direct scaling. Individual rMT corresponds to a constant cortical E‐field magnitude ratio across coil types. E‐field‐based prediction offers a more accurate, coil‐independent method for standardizing TMS intensity, reducing the need for repeated thresholding.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcranial Magnetic StimulationElectromagnetic FieldsMotor CortexHumansFemaleAdultMaleYoung AdultMagnetic Resonance ImagingEvoked Potentials, Motor

Stichwörter der Autor:innen

dosingelectrical field stimulationneuronavigationtranscranial magnetic stimulation

Autor:innen und Institutionen

  • Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA.
  • Harvard Medical School, Boston, Massachusetts, USA.
  • Department of Physical Therapy and Rehabilitation Science, MGH Institute of Health Professions, Boston, Massachusetts, USA.
  • Jefferson Moss Rehabilitation Research Institute, Philadelphia, Pennsylvania, USA.
  • Department of Rehabilitation Medicine, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
  • Worcester Polytechnic Institute, Worcester, Massachusetts, USA.

ORCID-Profile: Evgenii Kim, Keren Zhu, Danyal Fareed Bhutto, Teresa Jacobson Kimberley, Netri Pajankar, Parker Kotlarz, Sergey N Makaroff

Förderung

  • NIH HHS
  • NIMH NIH HHS
  • NIBIB NIH HHS
  • Chernowitz Medical Research Foundation
  • NINDS NIH HHS
  • NIDCD NIH HHS
  • National Institutes of Health

Zitieren

APA

Kim, E., Daneshzand, M., Zhu, K., Bhutto, D. F., Kimberley, T. J., Edwards, D., Pajankar, N., Kotlarz, P., Raij, T., Makaroff, S. N., & Nummenmaa, A. (2026). Standardizing TMS Intensity Across Different Coils Using Individualized Electric Field Modeling. Human Brain Mapping, 47(8). https://doi.org/10.1002/hbm.70550

Vancouver

Kim E, Daneshzand M, Zhu K, Bhutto DF, Kimberley TJ, Edwards D, et al. Standardizing TMS Intensity Across Different Coils Using Individualized Electric Field Modeling. Human Brain Mapping. 2026;47(8). doi:10.1002/hbm.70550

BibTeX
@article{Kim2026,
  author = {Kim, Evgenii and Daneshzand, Mohammad and Zhu, Keren and Bhutto, Danyal Fareed and Kimberley, Teresa Jacobson and Edwards, Dylan and Pajankar, Netri and Kotlarz, Parker and Raij, Tommi and Makaroff, Sergey N and Nummenmaa, Aapo},
  title = {Standardizing TMS Intensity Across Different Coils Using Individualized Electric Field Modeling},
  journal = {Human Brain Mapping},
  year = {2026},
  volume = {47},
  number = {8},
  doi = {10.1002/hbm.70550}
}
Kostenlos starten →