Cyclic 2.5D Perceptual Loss for Cross‐Modal 3D Medical Image Synthesis: T1w MRI to Tau PET
Human Brain Mapping · 01.04.2026 · 47 (5)
DOI: 10.1002/hbm.70508 ↗Kurz gefasst
Fachartikel in der Zeitschrift Human Brain Mapping, online erschienen am 12.04.2026. Verfasst von Junho Moon und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Artificial Intelligence Semiconductor Engineering, Hanyang University, Seoul, South Korea. Hauptthemen laut MEDLINE: Positron-Emission Tomography, Magnetic Resonance Imaging, tau Proteins, Imaging, Three-Dimensional. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 138 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIA NIH HHS, National Supercomputing Center, Korea Institute of Science and Technology Information, NCRR NIH HHS.
Abstract (Originalsprache)
Positron emission tomography (PET) provides an in vivo molecular marker for various diseases, including Alzheimer's disease and related dementias (ADRD). PET has become increasingly integrated into diagnostic decision‐making, disease staging, and clinical trial enrichment. However, its widespread use remains constrained by high costs, government regulations, and the invasiveness of radiotracer injection. Modern diagnostic frameworks emphasize the importance of multimodal biomarker assessment, such as the “amyloid/tau/neurodegeneration” (A/T/N) framework for Alzheimer's disease; however, they are constrained by these barriers. Medical image synthesis or translation offers a potential solution by enabling the reconstruction of unavailable modalities. The clinical utility of PET depends on accurately capturing regional uptake patterns rather than exact voxel‐wise intensities, motivating the use of perceptual loss functions to assess higher‐level semantic features in generative models. While 2D, 3D, and 2.5D perceptual losses are utilized in 3D synthesis, each encounters challenges, including limited volumetric context, the scarcity of pretrained 3D models, and difficulty balancing optimization across anatomical planes. In this work, we address cross‐modal synthesis of tau PET from structural magnetic resonance imaging (MRI), generating 3D pseudo‐[ 18 F]flortaucipir standardized uptake value ratio (SUVR) maps from 3D T1‐weighted MR images. We propose a cyclic 2.5D perceptual loss that cyclically optimizes the axial, coronal, and sagittal planes over training phases, thereby enhancing volumetric consistency. Furthermore, we standardize PET SUVRs by scanner manufacturer, reducing inter‐manufacturer variability and better preserving high‐uptake regions. We evaluate the proposed approach on cohorts spanning the ADRD spectrum using data from the Alzheimer's Disease Neuroimaging Initiative and the Standardized Centralized Alzheimer's Disease and Related Dementias Neuroimaging cohort. Our approach is broadly applicable across various generative frameworks and achieves high quantitative and qualitative performance on diverse architectures, including U‐Net, UNETR, SwinUNETR, CycleGAN, and Pix2Pix. Notably, it achieves better agreement between synthesized SUVRs and measured PET scans in key brain regions relevant to Alzheimer‐type tau pathology. The code is publicly available at https://github.com/labhai/Cyclic‐2.5D‐Perceptual‐Loss .
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Artificial Intelligence Semiconductor Engineering, Hanyang University, Seoul, South Korea.
- Department of Artificial Intelligence, Hanyang University, Seoul, South Korea.
- Department of Electronic Engineering, Hanyang University, Seoul, South Korea.
- Division of Computer Engineering, Hankuk University of Foreign Studies, Yongin, South Korea.
- Division of AI Data Convergence, Hankuk University of Foreign Studies, Yongin, South Korea.
- Division of Language & AI, Hankuk University of Foreign Studies, Seoul, South Korea.
ORCID-Profile: Junho Moon, Haejun Chung, Ikbeom Jang
Förderung
- NIA NIH HHS
- National Supercomputing Center, Korea Institute of Science and Technology Information
- NCRR NIH HHS
- NIDCD NIH HHS
- Artificial Intelligence Graduate School Program (Hanyang University), Ministry of Science and ICT (MSIT)
- RRD VA
- NIH HHS
- Korea National Institute of Health (KNIH)
Zitieren
APA
Moon, J., Kim, S., Chung, H., Jang, I., & Alzheimer's Disease Neuroimaging Initiative (2026). Cyclic 2.5D Perceptual Loss for Cross‐Modal 3D Medical Image Synthesis: T1w MRI to Tau PET. Human Brain Mapping, 47(5). https://doi.org/10.1002/hbm.70508
Vancouver
Moon J, Kim S, Chung H, Jang I, Alzheimer's Disease Neuroimaging Initiative. Cyclic 2.5D Perceptual Loss for Cross‐Modal 3D Medical Image Synthesis: T1w MRI to Tau PET. Human Brain Mapping. 2026;47(5). doi:10.1002/hbm.70508
BibTeX
@article{Moon2026,
author = {Moon, Junho and Kim, Symac and Chung, Haejun and Jang, Ikbeom and Alzheimer's Disease Neuroimaging Initiative, Alzheimer's Disease Neuroimaging Initiative},
title = {Cyclic 2.5D Perceptual Loss for Cross‐Modal 3D Medical Image Synthesis: T1w MRI to Tau PET},
journal = {Human Brain Mapping},
year = {2026},
volume = {47},
number = {5},
doi = {10.1002/hbm.70508}
}
EUVIMED