Vergleichsstudie in der Zeitschrift Human Brain Mapping, online erschienen am 27.09.2025. Verfasst von Tjerk P Gutteling und 6 weiteren Autor:innen. Beteiligte Einrichtung: CERMEP-Imagerie du Vivant, MEG Departement, Lyon, France. Hauptthemen laut MEDLINE: Magnetoencephalography, Electroencephalography, Evoked Potentials, Auditory, Auditory Perception. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Région Auvergne-Rhône-Alpes, Labex Cortex, France Life Imaging.
Abstract (Originalsprache)
Magneto‐encephalography (MEG) provides a higher spatial resolution than electro‐encephalography (EEG) to measure human auditory responses. However, conventional cryogenic MEG systems (SQUID‐MEG) suffer from severe technological restrictions limiting, for instance, routine clinical use. Fortunately, a new generation of MEG sensors, optically pumped magnetometers (OPMs), has been developed to bridge the gap, combining the wearability of EEG with the benefits of MEG signal acquisition. We aim to assess their potential for studying auditory mismatch processing. The auditory mismatch negativity (MMN) is a well‐characterized evoked component observable using a passive oddball paradigm with two‐tone sound sequences. It has been extensively described using both EEG and MEG and is part of many EEG‐based clinical applications, such as the assessment of patients with disorders of consciousness. MMN is therefore a relevant candidate to evaluate OPM performance. We use recently developed Helium‐OPMs, which are high dynamic range MEG sensors that operate at room temperature. We compare their performance with cryogenic SQUID‐MEG and EEG in a passive frequency oddball paradigm. Results show a significant MMN across subjects in all modalities as well as a high temporal similarity between modalities. Signal‐to‐noise ratios were also similar, and detection of significant individual MMN (within‐subjects) using the OPM system was equal to or better than EEG. Given that the OPM system tested here is a prototype comprised of only five sensors, these results are a promising step towards wearable MEG that combines the advantages of MEG and EEG.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- CERMEP-Imagerie du Vivant, MEG Departement, Lyon, France.
- CNRS, INSERM, Centre de Recherche en Neurosciences de Lyon CRNL U1028, UMR5292, COPHY, Université Claude Bernard Lyon 1, Bron, France.
- CNRS, INSERM, Centre de Recherche en Neurosciences de Lyon CRNL U1028, UMR5292, EDUWELL, Université Claude Bernard Lyon 1, Bron, France.
- MAG4Health, Grenoble, France.
ORCID-Profile: Tjerk P Gutteling, Julien Jung
Förderung
- Région Auvergne-Rhône-Alpes
- Labex Cortex
- France Life Imaging
Zitieren
APA
Gutteling, T. P., Mattout, J., Daligault, S., Jung, J., Labyt, E., Schwartz, D., & Lecaignard, F. (2025). The Mismatch Negativity Compared: EEG , SQUID ‐ MEG , and Novel 4 Helium ‐ OPMs. Human Brain Mapping, 46(14). https://doi.org/10.1002/hbm.70368
Vancouver
Gutteling TP, Mattout J, Daligault S, Jung J, Labyt E, Schwartz D, et al. The Mismatch Negativity Compared: EEG , SQUID ‐ MEG , and Novel 4 Helium ‐ OPMs. Human Brain Mapping. 2025;46(14). doi:10.1002/hbm.70368
BibTeX
@article{Gutteling2025,
author = {Gutteling, Tjerk P and Mattout, Jérémie and Daligault, Sébastien and Jung, Julien and Labyt, Etienne and Schwartz, Denis and Lecaignard, Françoise},
title = {The Mismatch Negativity Compared: EEG , SQUID ‐ MEG , and Novel 4 Helium ‐ OPMs},
journal = {Human Brain Mapping},
year = {2025},
volume = {46},
number = {14},
doi = {10.1002/hbm.70368}
}
EUVIMED