Ionic liquid‐based dispersive liquid–liquid microextraction of anthelmintic drug residues in small‐stock meat followed by LC‐ESI‐MS / MS detection
Food Science & Nutrition · 2023-10 · 11 (10) · 6288-6302
DOI: 10.1002/fsn3.3568 ↗Kurz gefasst
Fachartikel in der Zeitschrift Food Science & Nutrition, online erschienen am 22.07.2023. Verfasst von Rebagamang Tshepho und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, College of Science, Engineering and Technology, The Science Campus University of South Africa Roodepoort, Johannesburg South…. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: International Atomic Energy Agency.
Abstract (Originalsprache)
An ionic liquid‐based dispersive liquid–liquid microextraction (IL‐DLLME) of 20 anthelmintic drugs followed and detected by liquid chromatography–tandem mass spectrometry (LC–MS/MS) has been developed, optimized, and validated. The parameters affecting the anthelmintic extraction efficiencies such as selection of extraction solvent (ionic liquids), selection of disperser solvent, volume of extraction solvent, volume of disperser solvent, pH of the aqueous phase, extraction time, salt addition, and centrifugation time were optimized. Validation was conducted according to ISO/IEC 17025:2017 and Commission Implementing Regulation (EU) 2021/808 of 22 March 2021. Validation parameters such as calibration function, matrix effect, limit of detection (LOD), limit of quantification (LOQ), decision limit (CCα), accuracy, and precision were established. Coefficient of determination ( R 2 ) values ranging from .99938 to .99995 were obtained using the matrix calibration curve spiked at 0, 0.25, 1.0, 1.5, and 2.0 times MRL. The LODs and LOQs were calculated using the standard deviation of the response and the slopes of the calibration curves ranged from 0.35 to 26.1 μg/kg and from 1.2 to 87.0 μg/kg, respectively, and were dependent on calibration range. The CCα values ranged from 23 to 1022.0 μg/kg and are also dependent on the MRL concentration levels. The coefficient of variation (CV) values calculated are within the reproducibility range of 16%–30% adapted from the Horwitz Equation CV = 2 (1–0.5 log C) and ranged from 1.7% to 16.9%. The developed and validated and the standard QuEChERS method were compared. The IL‐DLLME LC–MS/MS method was applied to 32 small stock (18 caprine [goat] and 14 ovine [sheep]) liver samples received from municipal abattoirs at Botswana National Veterinary Laboratory for the analysis of anthelmintic drug residues. The results obtained indicated that the anthelmintic drug residues were all below the detection capability, and therefore, the samples were passed as fit for human consumption.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Chemistry, College of Science, Engineering and Technology, The Science Campus University of South Africa Roodepoort, Johannesburg South Africa.
- Residue Section Botswana National Veterinary Laboratory Gaborone Botswana.
- Institute for Nanotechnology and Water Sustainability (iNanoWS), The Science Campus, College of Science, Engineering and Technology (CSET) University of South Africa Roodepoort, Johannesburg South Africa.
ORCID-Profile: Mathew M Nindi
Förderung
- International Atomic Energy Agency
Zitieren
APA
Tshepho, R., Dube, S., & Nindi, M. M. (2023). Ionic liquid‐based dispersive liquid–liquid microextraction of anthelmintic drug residues in small‐stock meat followed by LC‐ESI‐MS / MS detection. Food Science & Nutrition, 11(10), 6288-6302. https://doi.org/10.1002/fsn3.3568
Vancouver
Tshepho R, Dube S, Nindi MM. Ionic liquid‐based dispersive liquid–liquid microextraction of anthelmintic drug residues in small‐stock meat followed by LC‐ESI‐MS / MS detection. Food Science & Nutrition. 2023;11(10):6288-6302. doi:10.1002/fsn3.3568
BibTeX
@article{Tshepho2023,
author = {Tshepho, Rebagamang and Dube, Simiso and Nindi, Mathew M},
title = {Ionic liquid‐based dispersive liquid–liquid microextraction of anthelmintic drug residues in small‐stock meat followed by LC‐ESI‐MS / MS detection},
journal = {Food Science & Nutrition},
year = {2023},
volume = {11},
number = {10},
pages = {6288--6302},
doi = {10.1002/fsn3.3568}
}
EUVIMED