AI‐enabled biomimetic flexible pressure sensors for high‐precision gait monitoring and rehabilitation assessment
FlexMat · 17.05.2026
DOI: 10.1002/flm2.70090 ↗Kurz gefasst
Fachartikel in der Zeitschrift FlexMat, online erschienen am 17.05.2026. Verfasst von Yingchun Li und 14 weiteren Autor:innen. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China.
Abstract (Originalsprache)
Flexible pressure sensors, owing to their excellent comfort, flexibility, and adaptability, have emerged as promising candidates for applications in smart healthcare and rehabilitation training. However, challenges such as suboptimal sensing performance, insufficient stability, integration difficulties, and the real‐time interpretation of pathological gait characteristics still severely constrain their reliability and practicality in wearable applications. Here, we report multilayer microstructured capacitive sensors based on hierarchical polymer composites. These sensors demonstrate ultrahigh sensitivity (24.3% kPa −1 ), an ultralow detection limit (0.49 Pa), a broad pressure range (up to 500 kPa), and outstanding mechanical stability over 6000 loading‐unloading cycles. Finite element simulations reveal that both the TPU/Ag electrospun nanofiber film and the porous dielectric layer undergo compression under loading, thereby enhancing the air‐gap effect and dielectric properties, which collectively boost sensing sensitivity. The simulations further validate the working mechanism of the sensors under different pressure conditions, in good agreement with experimental results. Moreover, the sensors exhibit excellent stability even under extreme pressures (e.g., during automobile driving), and can be applied in human joint motion monitoring and encrypted communication recognition. By embedding artificial intelligence algorithms, spatiotemporal pressure data collected by sensor arrays are decoded and wirelessly transmitted to a mobile application. These models achieve 98.96% accuracy in detecting gait recovery stages of patients after knee surgery and 99.44% accuracy in classifying six rehabilitation training gait patterns, thereby laying a solid foundation for the development of next‐generation high‐performance intelligent insoles based on flexible pressure sensors.
Förderung
- National Natural Science Foundation of China
- National Key Research and Development Program of China
Zitieren
APA
Li, Y., Ding, Y., Lei, K., Zhang, Y., Lin, Z., Sun, J., Guo, K., Zheng, Y., Tan, S., Zhang, X., Li, X., Hao, Y., Li, X., Liu, Y., & Chang, J. (2026). AI‐enabled biomimetic flexible pressure sensors for high‐precision gait monitoring and rehabilitation assessment. FlexMat. https://doi.org/10.1002/flm2.70090
Vancouver
Li Y, Ding Y, Lei K, Zhang Y, Lin Z, Sun J, et al. AI‐enabled biomimetic flexible pressure sensors for high‐precision gait monitoring and rehabilitation assessment. FlexMat. 2026. doi:10.1002/flm2.70090
BibTeX
@article{Li2026,
author = {Li, Yingchun and Ding, Yarong and Lei, Kaixin and Zhang, Yuze and Lin, Zhenhua and Sun, Jiachun and Guo, Kaitai and Zheng, Yang and Tan, Shaozhe and Zhang, Xuesi and Li, Xinyue and Hao, Yue and Li, Xiangning and Liu, Yannan and Chang, Jingjing},
title = {AI‐enabled biomimetic flexible pressure sensors for high‐precision gait monitoring and rehabilitation assessment},
journal = {FlexMat},
year = {2026},
doi = {10.1002/flm2.70090}
}
EUVIMED