EUVIMEDEUVIMED entdecken
Crossref

Thoracic electrical impedance tomography using a two‐plane electrode configuration in horses

Nicole Studer iD, David Byrne iD, Anthea Raisis, Andy Adler, Jesslyn Cheong, Cristy Secombe iD, Johannes Peter Schramel, Martina Mosing

Equine Veterinary Journal · 28.05.2026

DOI: 10.1002/evj.70188 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Equine Veterinary Journal, online erschienen am 28.05.2026. Verfasst von Nicole Studer und 7 weiteren Autor:innen. Beteiligte Einrichtung: Animalius Vet, Bayswater, Western Australia, Australia. Die Arbeit nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Traditional one‐plane (oneP) electrical impedance tomography (EIT) electrode configurations limit evaluation to a convex lens‐shaped lung slice, prone to overrepresentation of central areas. Two‐plane (twoP) EIT is expected to refine this technique and result in more representative lung imaging.

Objectives

To compare ventilation distribution using single slice reconstructions, obtained with twoP or oneP. Study Design Computational modelling and in vivo exploratory randomised experimental trial.

Methods

A finite element simulation model of oneP and twoP was calculated to estimate captured lung fields. Thereafter, twoP and oneP EIT data were collected in 20 standing horses at baseline, during stance variations and rebreathing. A visual functional region of interest representing the lung field was defined and EIT data reconstructed. Centres of ventilation (CoV), regional ventilation (∆Z, expressed as L or R for left or right lung, and D, CD, CV, or V for dorsal, central dorsal, central ventral or ventral regions) and tidal impedance variation (TIV) were compared between configurations at baseline and between baseline and challenge measurements using Wilcoxon matched pairs signed rank test and a mixed effect model. Proportional changes were compared using a paired t ‐test.

Results

The simulation revealed a more evenly distributed vertical sensitivity with twoP compared to oneP. In vivo data were analysed to determine which EIT regional parameters increased (twoP vs. oneP). At baseline, ∆ZL D , ∆ZR D and CoV VD , were higher when using twoP (7.1 (5.9–8.0) vs. 2.2 (0.9–3.5): p < 0.001; 6.4 (5.6–7.5) vs. 1.5 (0.5–2.79): p < 0.001; 47.7 (46.8–49.29) vs. 43.3 (42.2–45.8): p < 0.001). With rebreathing, an increase in TIV and CoV VD was seen with both belt configurations (oneP: 25.13 (±1.967) vs. 49.39 (±11.27): p < 0.001 and 44.3 (±2.300) vs. 45.64 (±2.243): p = 0.002; twoP: 20.21 (±7.398) vs. 49.6 (±13.09): p < 0.001 and 48.79 (±2.126) vs. 50.38 (±1.783): p = 0.005).

Conclusions

TwoP EIT reconstructions resulted in a more vertically uniform representation of ventilation in simulation and in vivo. This likely results in an enhanced representation of peripheral lung fields.

Schlagwörter

Stichwörter der Autor:innen

dorsal lung fieldhorsetwo‐plane EITventilation distributionvertical sensitivity

Autor:innen und Institutionen

  • Animalius Vet, Bayswater, Western Australia, Australia.
  • School of Veterinary Medicine, Murdoch University, Perth, Western Australia, Australia.
  • Department of Systems and Computer Engineering, Carleton University, Ottawa, Ontario, Canada.
  • Anaesthesia Service, CityU Veterinary Medical Centre, Kowloon, Hong Kong.
  • Anaesthesiology and Intensive Care, Clinical Centre of Small Animal Health and Research, Clinical Department for Small Animals and Horses, University of Veterinary Medicine, Vienna, Austria.

ORCID-Profile: Nicole Studer, David Byrne, Cristy Secombe

Zitieren

APA

Studer, N., Byrne, D., Raisis, A., Adler, A., Cheong, J., Secombe, C., Schramel, J. P., & Mosing, M. (2026). Thoracic electrical impedance tomography using a two‐plane electrode configuration in horses. Equine Veterinary Journal. https://doi.org/10.1002/evj.70188

Vancouver

Studer N, Byrne D, Raisis A, Adler A, Cheong J, Secombe C, et al. Thoracic electrical impedance tomography using a two‐plane electrode configuration in horses. Equine Veterinary Journal. 2026. doi:10.1002/evj.70188

BibTeX
@article{Studer2026,
  author = {Studer, Nicole and Byrne, David and Raisis, Anthea and Adler, Andy and Cheong, Jesslyn and Secombe, Cristy and Schramel, Johannes Peter and Mosing, Martina},
  title = {Thoracic electrical impedance tomography using a two‐plane electrode configuration in horses},
  journal = {Equine Veterinary Journal},
  year = {2026},
  doi = {10.1002/evj.70188}
}
Kostenlos starten →