EUVIMEDEUVIMED entdecken
Crossref

EIS Mimicking DC Measurement Technique: A Novel Path for Battery Aging Analysis

Sabri Hakan Sakallıoğlu, Koray Bahadır Dönmez, Burak Onur

Energy Storage · 2025-08 · 7 (5)

DOI: 10.1002/est2.70229 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energy Storage, online erschienen am 15.07.2025. Verfasst von Sabri Hakan Sakallıoğlu und 2 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: Türkiye Bilimsel ve Teknolojik Araştırma Kurumu.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrochemical impedance spectroscopy (EIS), an alternating current (AC) technique, is commonly employed to monitor the aging process of lithium‐ion batteries (LIBs). However, its use requires sophisticated electrochemical equipment, which not only complicates battery management systems (BMS) but also raises overall costs. Moreover, analyzing EIS data often requires expert‐level interpretation. In this study, we investigated the applicability of various direct current (DC) methods for tracking the total internal resistance (T‐IR) during the aging process. We evaluated the accuracy of their potential use in estimating the State of Health (SoH). The performance of these DC methods was compared with classical EIS techniques to identify the most reliable conditions for accurate SoH estimation. Among the techniques explored, one method involved applying a low current to the battery and determining T‐IR based on the real‐time voltage response, thereby mimicking the EIS approach. This method demonstrated the highest accuracy compared to classical EIS results. Additionally, we evaluated the impact of high‐DC pulses on T‐IR and analyzed its variation with the state of charge (SoC), comparing these findings with EIS‐derived data. Our results indicate that low‐DC techniques not only provide reliable T‐IR measurements but also offer a cost‐effective and simpler alternative for SoH monitoring in BMS and laboratory applications. The EIS‐mimicking low‐DC approach, in particular, shows promise as a versatile tool for determining the T‐IR of electrochemical cells under various operational scenarios.

Förderung

  • Türkiye Bilimsel ve Teknolojik Araştırma Kurumu

Zitieren

APA

Sakallıoğlu, S. H., Dönmez, K. B., & Onur, B. (2025). EIS Mimicking DC Measurement Technique: A Novel Path for Battery Aging Analysis. Energy Storage, 7(5). https://doi.org/10.1002/est2.70229

Vancouver

Sakallıoğlu SH, Dönmez KB, Onur B. EIS Mimicking DC Measurement Technique: A Novel Path for Battery Aging Analysis. Energy Storage. 2025;7(5). doi:10.1002/est2.70229

BibTeX
@article{Sakallolu2025,
  author = {Sakallıoğlu, Sabri Hakan and Dönmez, Koray Bahadır and Onur, Burak},
  title = {EIS Mimicking DC Measurement Technique: A Novel Path for Battery Aging Analysis},
  journal = {Energy Storage},
  year = {2025},
  volume = {7},
  number = {5},
  doi = {10.1002/est2.70229}
}
Kostenlos starten →