EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Power Quality Enhancement of PMSG Wind Energy Systems Using a Multilevel DVR With a PSO‐Optimized BESS

Ahmed Muthanna Nori, Ali Kadhim Abdulabbas, Ameer L. Saleh, Nabil Mohammed, László Számel

Energy Science & Engineering · 18.11.2026

DOI: 10.1002/ese3.70704 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energy Science & Engineering, online erschienen am 18.11.2026. Verfasst von Ahmed Muthanna Nori und 4 weiteren Autor:innen. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper introduces a protection scheme for a grid‐connected wind‐turbine power‐conversion system employing a Permanent Magnet Synchronous Generator (PMSG), a dynamic voltage restorer (DVR), and a battery energy storage system (BESS). The BESS is integrated into the DC‐link through a bidirectional buck‐boost converter (BBBC) to support voltage regulation during wind‐speed fluctuations and grid disturbances. Particle swarm optimization (PSO) is used offline to tune the BBBC PI‐controller parameters, improving DC‐link voltage regulation through BESS charging and discharging. The AC side of the DVR is connected in series with the PMSG terminal, while its DC side is coupled to the DC bus. A three‐level Neutral Point Clamped Multi‐Level Inverter (NPC‐MLI) is employed for the DVR and is activated during voltage sags and swells affecting the terminal voltage. The proposed scheme was evaluated using MATLAB/Simulink under varying wind speeds and different grid‐disturbance conditions. Compared with the two‐level DVR, the three‐level NPC‐based DVR reduced the PMSG terminal‐voltage THD from 0.41%–0.62% to 0.28%–0.54% under the investigated voltage‐sag faults and from 0.36%–0.53% to 0.19%–0.48% under asymmetric and symmetric voltage‐swell conditions. Moreover, compared with the conventional PI controller, the PSO‐tuned PI controller reduced DC‐link voltage overshoot and undershoot under wind‐speed variation, voltage sag, and voltage swell conditions, while providing shorter settling times during voltage sag and swell and maintaining the DC‐link voltage close to its reference throughout the investigated wind‐speed variations. These improvements were demonstrated in MATLAB/Simulink for the investigated parameter set and disturbance scenarios.

Zitieren

APA

Nori, A. M., Abdulabbas, A. K., Saleh, A. L., Mohammed, N., & Számel, L. (2026). Power Quality Enhancement of PMSG Wind Energy Systems Using a Multilevel DVR With a PSO‐Optimized BESS. Energy Science & Engineering. https://doi.org/10.1002/ese3.70704

Vancouver

Nori AM, Abdulabbas AK, Saleh AL, Mohammed N, Számel L. Power Quality Enhancement of PMSG Wind Energy Systems Using a Multilevel DVR With a PSO‐Optimized BESS. Energy Science & Engineering. 2026. doi:10.1002/ese3.70704

BibTeX
@article{Nori2026,
  author = {Nori, Ahmed Muthanna and Abdulabbas, Ali Kadhim and Saleh, Ameer L. and Mohammed, Nabil and Számel, László},
  title = {Power Quality Enhancement of PMSG Wind Energy Systems Using a Multilevel DVR With a PSO‐Optimized BESS},
  journal = {Energy Science & Engineering},
  year = {2026},
  doi = {10.1002/ese3.70704}
}
Kostenlos starten →