Fault‐Specific Diagnostic Regions Based on Normalized DC Voltage and Current Indices for Photovoltaic Systems Using Routine Inverter and Environmental Data
Energy Science & Engineering · 2026-11 · 14 (11) · 5294-5310
DOI: 10.1002/ese3.70654 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energy Science & Engineering, online erschienen am 24.09.2026. Verfasst von Woo Gyun Shin und 5 weiteren Autor:innen. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The growing deployment of photovoltaic (PV) systems has increased the need for practical data‐driven approaches to support reliable operation and maintenance (O&M). However, direct current (DC) voltage and current are highly sensitive to environmental and operating conditions, while many diagnostic approaches require infrared (IR) or electroluminescence (EL) imaging, current–voltage (I–V) curve tracing, or additional sensors. This study defines fault‐specific diagnostic regions based on normalized DC voltage and current indices for PV systems using routine inverter and environmental data. Fault‐induced maximum power point (MPP) shifts were analyzed using measured I–V curves, and normalized voltage and current indices were derived from inverter‐collected DC voltage and current under normal and emulated fault conditions. The diagnostic regions characterized normal and fault conditions at string and array levels, and classifier‐based evaluation confirmed their separability. The neural network achieved the best performance, with 99.9% validation accuracy and a 99.8% F1‐score. The method was validated on a 3‐kW PV system and applied to operational data from a 387‐kW PV plant. In the field system, actual faults, including multiple blown string fuses, were identified. After fault correction, the DC performance ratio increased by approximately 40%. These results support PV system monitoring and maintenance without additional measurement equipment.
Zitieren
APA
Shin, W. G., Lee, J. S., Ju, Y. C., Hwang, H. M., Lim, J., & Ko, S. W. (2026). Fault‐Specific Diagnostic Regions Based on Normalized DC Voltage and Current Indices for Photovoltaic Systems Using Routine Inverter and Environmental Data. Energy Science & Engineering, 14(11), 5294-5310. https://doi.org/10.1002/ese3.70654
Vancouver
Shin WG, Lee JS, Ju YC, Hwang HM, Lim J, Ko SW. Fault‐Specific Diagnostic Regions Based on Normalized DC Voltage and Current Indices for Photovoltaic Systems Using Routine Inverter and Environmental Data. Energy Science & Engineering. 2026;14(11):5294-5310. doi:10.1002/ese3.70654
BibTeX
@article{Shin2026,
author = {Shin, Woo Gyun and Lee, Jin Seok and Ju, Young Chul and Hwang, Hye Mi and Lim, Jongchul and Ko, Suk Whan},
title = {Fault‐Specific Diagnostic Regions Based on Normalized DC Voltage and Current Indices for Photovoltaic Systems Using Routine Inverter and Environmental Data},
journal = {Energy Science & Engineering},
year = {2026},
volume = {14},
number = {11},
pages = {5294--5310},
doi = {10.1002/ese3.70654}
}
EUVIMED