EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of Tunnel Ventilation on Hydrogen Dispersion From Leaks in Hydrogen Fuel Cell Trucks

Limin Geng, Shiyu Shan, Zongxue Yan, Nan Gao, Dong Huang, Zhao Gao, Xinxin Cao

Energy Science & Engineering · 2026-08 · 14 (8) · 3608-3624

DOI: 10.1002/ese3.70547 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energy Science & Engineering, online erschienen am 27.04.2026. Verfasst von Limin Geng und 6 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The widespread adoption of hydrogen fuel cell trucks (HFCTs) depends on addressing hydrogen safety concerns, particularly in confined spaces like tunnels, where effective ventilation is crucial to prevent accumulation during leaks. This study uses a computational fluid dynamics (CFD) model to simulate hydrogen dispersion and evaluates key ventilation factors—velocity, area, placement, and spacing. An orthogonal sensitivity analysis identifies vent area as the dominant parameter, leading to the optimal ventilation strategy. The results confirm that increasing ventilation velocity and vent cross‐sectional area significantly improve hydrogen exhaust efficiency. Specifically, increasing ventilation velocity from 5 to 20 m/s reduced the flammable cloud volume by 55.35%, while expanding the vent area from 1 to 4 m 2 reduced it by 49.62%. The vent cross‐sectional area was identified as the most influential parameter. Furthermore, top‐mounted vent placement proved more effective than sidewall configurations, and a 50 m longitudinal spacing outperformed 100 m in minimizing the hydrogen cloud. Consequently, the optimal ventilation configuration is a system with a velocity of 20 m/s, top‐mounted vents, a cross‐sectional area of 4 m 2 , and 50 m spacing.

Zitieren

APA

Geng, L., Shan, S., Yan, Z., Gao, N., Huang, D., Gao, Z., & Cao, X. (2026). Effect of Tunnel Ventilation on Hydrogen Dispersion From Leaks in Hydrogen Fuel Cell Trucks. Energy Science & Engineering, 14(8), 3608-3624. https://doi.org/10.1002/ese3.70547

Vancouver

Geng L, Shan S, Yan Z, Gao N, Huang D, Gao Z, et al. Effect of Tunnel Ventilation on Hydrogen Dispersion From Leaks in Hydrogen Fuel Cell Trucks. Energy Science & Engineering. 2026;14(8):3608-3624. doi:10.1002/ese3.70547

BibTeX
@article{Geng2026,
  author = {Geng, Limin and Shan, Shiyu and Yan, Zongxue and Gao, Nan and Huang, Dong and Gao, Zhao and Cao, Xinxin},
  title = {Effect of Tunnel Ventilation on Hydrogen Dispersion From Leaks in Hydrogen Fuel Cell Trucks},
  journal = {Energy Science & Engineering},
  year = {2026},
  volume = {14},
  number = {8},
  pages = {3608--3624},
  doi = {10.1002/ese3.70547}
}
Kostenlos starten →