EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

CFD modeling of a triple‐walled direct absorption evacuated tube solar collector based on hybrid nanofluid/microencapsulated PCM

Niloofar Shahini, Maryam Karami, Mohammad Ali Akhavan‐Behabadi

Energy Science & Engineering · 2024-05 · 12 (5) · 2297-2318

DOI: 10.1002/ese3.1741 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energy Science & Engineering, 2024-04. Verfasst von Niloofar Shahini und 2 weiteren Autor:innen. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nowadays, direct absorption solar collectors are a new concept of solar collectors which have attracted special attention. The type of heat transfer fluid (HTF) has a significant influence on the efficiency of this kind of collector. Therefore, in this study, a wide range of working fluids including mono nanofluid ( and CuO), binary nanofluid, and especially the incorporation of a new hybrid combination of nanofluid and microencapsulated phase change material (MPCM), are used as the working fluids of a triple‐walled direct absorption evacuated tube solar collector. The computational fluid dynamics (CFD) method is used for simulating the collector and investigating the effect of different parameters including volume fraction, base fluid, mass flow rate, and type of absorber tube structure (double‐ and triple‐walled) on collector thermal performance. Results show that binary nanofluids of 0.06% /0.002% CuO/water and 0.06% /0.002% CuO/ethylene glycol (EG) have the largest working fluid temperature differentials equal to 48.31 and 66.5 K, respectively. It was inferred that, at the mass flow rate of 2.7 , the efficiency is obtained to be 60.29% employing binary/EG nanofluid, which is 8.68% and 15.31% higher than CuO/EG and /EG nanofluids, respectively. Inserting the hybrid CuO nanofluid/MPCM leads to an improvement of 1.14% and 1.22% in the efficiency of triple‐ and double‐walled collectors, respectively, with respect to the individual usage of the nanofluid. The thermal efficiency of the double‐walled structure is higher than triple‐walled considering all HTFs.

Zitieren

APA

Shahini, N., Karami, M., & Akhavan‐Behabadi, M. A. (2024). CFD modeling of a triple‐walled direct absorption evacuated tube solar collector based on hybrid nanofluid/microencapsulated PCM. Energy Science & Engineering, 12(5), 2297-2318. https://doi.org/10.1002/ese3.1741

Vancouver

Shahini N, Karami M, Akhavan‐Behabadi MA. CFD modeling of a triple‐walled direct absorption evacuated tube solar collector based on hybrid nanofluid/microencapsulated PCM. Energy Science & Engineering. 2024;12(5):2297-2318. doi:10.1002/ese3.1741

BibTeX
@article{Shahini2024,
  author = {Shahini, Niloofar and Karami, Maryam and Akhavan‐Behabadi, Mohammad Ali},
  title = {CFD modeling of a triple‐walled direct absorption evacuated tube solar collector based on hybrid nanofluid/microencapsulated PCM},
  journal = {Energy Science & Engineering},
  year = {2024},
  volume = {12},
  number = {5},
  pages = {2297--2318},
  doi = {10.1002/ese3.1741}
}
Kostenlos starten →