EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Practical measurements distinguishing physiological and pathological stereoelectroencephalography channels based on high‐frequency oscillations in the human brain

Zilin Li iD, Baotian Zhao iD, Wenhan Hu, Chao Zhang, Xiu Wang, Chang Liu, Jiajie Mo iD, Zhihao Guo, Bowen Yang iD, Yuan Yao iD, Xiaoqiu Shao, Jianguo Zhang und 1 weitere

Epilepsia Open · 2024

DOI: 10.1002/epi4.12950 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Epilepsia Open, 2024. Verfasst von Zilin Li und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Electroencephalography, Epilepsies, Partial, Machine Learning. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China, Capital's Funds for Health Improvement and Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The present study aimed to identify various distinguishing features for use in the accurate classification of stereoelectroencephalography (SEEG) channels based on high‐frequency oscillations (HFOs) inside and outside the epileptogenic zone (EZ).

Methods

HFOs were detected in patients with focal epilepsy who underwent SEEG. Subsequently, HFOs within the seizure‐onset and early spread zones were defined as pathological HFOs, whereas others were defined as physiological. Three features of HFOs were identified at the channel level, namely, morphological repetition, rhythmicity, and phase–amplitude coupling (PAC). A machine‐learning (ML) classifier was then built to distinguish two HFO types at the channel level by application of the above‐mentioned features, and the contributions were quantified. Further verification of the characteristics and classifier performance was performed in relation to various conscious states, imaging results, EZ location, and surgical outcomes.

Results

Thirty‐five patients were included in this study, from whom 166 104 pathological HFOs in 255 channels and 53 374 physiological HFOs in 282 channels were entered into the analysis pipeline. The results revealed that the morphological repetitions of pathological HFOs were markedly higher than those of the physiological HFOs; this was also observed for rhythmicity and PAC. The classifier exhibited high accuracy in differentiating between the two forms of HFOs, as indicated by an area under the curve (AUC) of 0.89. Both PAC and rhythmicity contributed significantly to this distinction. The subgroup analyses supported these findings. Significance The suggested HFO features can accurately distinguish between pathological and physiological channels substantially improving its usefulness in clinical localization. Plain Language Summary In this study, we computed three quantitative features associated with HFOs in each SEEG channel and then constructed a machine learning‐based classifier for the classification of pathological and physiological channels. The classifier performed well in distinguishing the two channel types under different levels of consciousness as well as in terms of imaging results, EZ location, and patient surgical outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectroencephalographyEpilepsies, PartialMachine LearningHumansFemaleMaleAdultBrainAdolescentYoung AdultMiddle AgedChildStereotaxic Techniques

Stichwörter der Autor:innen

HFOs classificationepilepsy surgeryepileptogenic zonehigh‐frequency oscillationsintracranial electroencephalography

Autor:innen und Institutionen

  • Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
  • Stereotactic and Functional Neurosurgery Laboratory, Beijing Neurosurgical Institute, Capital Medical University, Beijing, China.
  • Beijing Key Laboratory of Neurostimulation, Beijing, China.
  • Department of Neurology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.

ORCID-Profile: Zilin Li, Baotian Zhao, Jiajie Mo, Bowen Yang, Yuan Yao

Förderung

  • National Natural Science Foundation of China
  • National Key Research and Development Program of China
  • Capital's Funds for Health Improvement and Research

Zitieren

APA

Li, Z., Zhao, B., Hu, W., Zhang, C., Wang, X., Liu, C., Mo, J., Guo, Z., Yang, B., Yao, Y., Shao, X., Zhang, J., & Zhang, K. (2024). Practical measurements distinguishing physiological and pathological stereoelectroencephalography channels based on high‐frequency oscillations in the human brain. Epilepsia Open. https://doi.org/10.1002/epi4.12950

Vancouver

Li Z, Zhao B, Hu W, Zhang C, Wang X, Liu C, et al. Practical measurements distinguishing physiological and pathological stereoelectroencephalography channels based on high‐frequency oscillations in the human brain. Epilepsia Open. 2024. doi:10.1002/epi4.12950

BibTeX
@article{Li2024,
  author = {Li, Zilin and Zhao, Baotian and Hu, Wenhan and Zhang, Chao and Wang, Xiu and Liu, Chang and Mo, Jiajie and Guo, Zhihao and Yang, Bowen and Yao, Yuan and Shao, Xiaoqiu and Zhang, Jianguo and Zhang, Kai},
  title = {Practical measurements distinguishing physiological and pathological stereoelectroencephalography channels based on high‐frequency oscillations in the human brain},
  journal = {Epilepsia Open},
  year = {2024},
  doi = {10.1002/epi4.12950}
}
Kostenlos starten →