Feasibility of high‐density electric source imaging in the presurgical workflow: Effect of number of spikes and automated spike detection
Epilepsia Open · 2023
DOI: 10.1002/epi4.12732 ↗Kurz gefasst
Fachartikel in der Zeitschrift Epilepsia Open, 2023. Verfasst von Ev-Christin Heide und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, University Medical Center, Georg-August University, Göttingen, Germany. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Epilepsy. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
Presurgical high‐density electric source imaging (hdESI) of interictal epileptic discharges (IEDs) is only used by few epilepsy centers. One obstacle is the time‐consuming workflow both for recording as well as for visual review. Therefore, we analyzed the effect of (a) an automated IED detection and (b) the number of IEDs on the accuracy of hdESI and time‐effectiveness.
Methods
In 22 patients with pharmacoresistant focal epilepsy receiving epilepsy surgery (Engel 1) we retrospectively detected IEDs both visually and semi‐automatically using the EEG analysis software Persyst in 256‐channel EEGs. The amount of IEDs, the Euclidean distance between hdESI maximum and resection zone, and the operator time were compared. Additionally, we evaluated the intra‐individual effect of IED quantity on the distance between hdESI maximum of all IEDs and hdESI maximum when only a reduced amount of IEDs were included.
Results
There was no significant difference in the number of IEDs between visually versus semi‐automatically marked IEDs (74 ± 56 IEDs/patient vs 116 ± 115 IEDs/patient). The detection method of the IEDs had no significant effect on the mean distances between resection zone and hdESI maximum (visual: 26.07 ± 31.12 mm vs semi‐automated: 33.6 ± 34.75 mm). However, the mean time needed to review the full datasets semi‐automatically was shorter by 275 ± 46 min (305 ± 72 min vs 30 ± 26 min, P < 0.001). The distance between hdESI of the full versus reduced amount of IEDs of the same patient was smaller than 1 cm when at least a mean of 33 IEDs were analyzed. There was a significantly shorter intraindividual distance between resection zone and hdESI maximum when 30 IEDs were analyzed as compared to the analysis of only 10 IEDs ( P < 0.001). Significance Semi‐automatized processing and limiting the amount of IEDs analyzed (~30–40 IEDs per cluster) appear to be time‐saving clinical tools to increase the practicability of hdESI in the presurgical work‐up.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurology, University Medical Center, Georg-August University, Göttingen, Germany.
- Institute for Diagnostic and Interventional Neuroradiology, University Medical Center, Georg-August University, Göttingen, Germany.
ORCID-Profile: Ev-Christin Heide, Daniel van de Velden, David Garnica Agudelo, Niels K Focke
Zitieren
APA
Heide, E. C., van de Velden, D., Garnica Agudelo, D., Hewitt, M., Riedel, C., & Focke, N. K. (2023). Feasibility of high‐density electric source imaging in the presurgical workflow: Effect of number of spikes and automated spike detection. Epilepsia Open. https://doi.org/10.1002/epi4.12732
Vancouver
Heide EC, van de Velden D, Garnica Agudelo D, Hewitt M, Riedel C, Focke NK. Feasibility of high‐density electric source imaging in the presurgical workflow: Effect of number of spikes and automated spike detection. Epilepsia Open. 2023. doi:10.1002/epi4.12732
BibTeX
@article{Heide2023,
author = {Heide, Ev-Christin and van de Velden, Daniel and Garnica Agudelo, David and Hewitt, Manuel and Riedel, Christian and Focke, Niels K},
title = {Feasibility of high‐density electric source imaging in the presurgical workflow: Effect of number of spikes and automated spike detection},
journal = {Epilepsia Open},
year = {2023},
doi = {10.1002/epi4.12732}
}
EUVIMED