Complementary predictive value of electromagnetic source imaging and hemodynamic responses in epilepsy surgery: A quantitative spatial analysis
Epilepsia · 2026
DOI: 10.1002/epi.70347 ↗Kurz gefasst
Fachartikel in der Zeitschrift Epilepsia, 2026. Verfasst von Chifaou Abdallah und 13 weiteren Autor:innen. Beteiligte Einrichtung: Montreal Neurological Institute and Hospital, McGill University, Montréal, Québec, Canada. Hauptthemen laut MEDLINE: Electroencephalography, Magnetoencephalography, Drug Resistant Epilepsy, Hemodynamics. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Fonds de Recherche du Québec - Santé, Savoy Foundation, CIHR.
Abstract (Originalsprache)
Objective
Accurate presurgical evaluation should assess not only the location but also the spatial extent of epileptic activity relative to the surgical cavity, a practical approximation of the epileptogenic zone. We evaluated how electromagnetic source imaging (EMSI) and hemodynamic responses to epileptic discharges relate to the surgical cavity and postoperative outcome, and whether multimodal concordance improves surgical prediction.
Methods
Consecutive patients with drug‐resistant focal epilepsy who underwent electroencephalography/magnetoencephalography (EEG/MEG), and EEG/functional magnetic resonance imaging (EEG/fMRI) followed by surgery and ≥1‐year postoperative follow‐up were included. EMSI was performed using maximum entropy on the mean. The most significant fMRI cluster was extracted. All results were projected onto a common cortical surface. Spatial concordance with the surgical cavity was quantified using spatial overlap (area under the receiver operating characteristic curve [AUC]), distance localization error (DLE), and spatial dispersion (SD). Predictive performance was evaluated using a combined spatial criterion (AUC >0.70 and DLE = 0 mm).
Results
Twenty‐five patients were included. EEG/MEG, EEG/fMRI, and multimodal analyses were contributive in 23, 14, and 12 patients, respectively. In the EEG/MEG group ( n = 23), patients with good outcome showed higher spatial overlap (mean ± standard deviation, AUC: 0.70 ± 0.14 vs 0.56 ± 0.18; p = 0.04), shorter DLE (4.83 ± 6.80 mm vs 17.98 ± 14.39 mm; p = 0.02), and a trend toward lower SD (24.45 ± 17.07 mm vs 34.21 ± 14.22 mm; p = 0.08) than patients with poor outcome. EEG/fMRI ( n = 14) exhibited similar trends without statistical significance. In predicting surgical outcome, EMSI achieved a negative predictive value of 62% and an accuracy of 61%, whereas EEG/fMRI reached 83% and 86%, respectively. When both modalities were considered ( n = 12), all patients with concordant resected findings achieved a good outcome, whereas 8 of 10 patients with discordant results did not. Significance EEG/MEG and EEG/fMRI showed complementary profiles. Resection of EEG/MEG localizations were more frequently associated with good outcome, whereas unresected EEG/fMRI responses predicted poor outcome. Concordant and resected multimodal findings were associated with good outcome, supporting a quantitative multimodal approach in presurgical evaluation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Montreal Neurological Institute and Hospital, McGill University, Montréal, Québec, Canada.
- Multimodal Functional Imaging Lab, Biomedical Engineering Department, McGill University, Montréal, Québec, Canada.
- Multimodal Functional Imaging Lab, Department of Physics, Concordia University, Montréal, Québec, Canada.
- Department of Neurology and Peter O'Donnell Jr. Brain Institute, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
- Department of Biomedical Engineering, Duke Pratt School of Engineering, Durham, North Carolina, USA.
- Department of Neurology, Duke University Medical Center, Durham, North Carolina, USA.
ORCID-Profile: Chifaou Abdallah, Edouard Delaire, Arielle Dascal, Aura González, Zhengchen Cai, Tanguy Hedrich, Hassan Khajehpour, Satoru Ikemoto, Boris C Bernhardt, Eliane Kobayashi, Jean Gotman, Birgit Frauscher, Christophe Grova
Förderung
- Fonds de Recherche du Québec - Santé
- Savoy Foundation
- CIHR
- Canadian Institutes of Health Research
Zitieren
APA
Abdallah, C., Delaire, E., Dascal, A., González, A., Cai, Z., Hedrich, T., Khajehpour, H., Ikemoto, S., Tanaka, M., Bernhardt, B. C., Kobayashi, E., Gotman, J., Frauscher, B., & Grova, C. (2026). Complementary predictive value of electromagnetic source imaging and hemodynamic responses in epilepsy surgery: A quantitative spatial analysis. Epilepsia. https://doi.org/10.1002/epi.70347
Vancouver
Abdallah C, Delaire E, Dascal A, González A, Cai Z, Hedrich T, et al. Complementary predictive value of electromagnetic source imaging and hemodynamic responses in epilepsy surgery: A quantitative spatial analysis. Epilepsia. 2026. doi:10.1002/epi.70347
BibTeX
@article{Abdallah2026,
author = {Abdallah, Chifaou and Delaire, Edouard and Dascal, Arielle and González, Aura and Cai, Zhengchen and Hedrich, Tanguy and Khajehpour, Hassan and Ikemoto, Satoru and Tanaka, Masataka and Bernhardt, Boris C and Kobayashi, Eliane and Gotman, Jean and Frauscher, Birgit and Grova, Christophe},
title = {Complementary predictive value of electromagnetic source imaging and hemodynamic responses in epilepsy surgery: A quantitative spatial analysis},
journal = {Epilepsia},
year = {2026},
doi = {10.1002/epi.70347}
}
EUVIMED