EUVIMEDEUVIMED entdecken
Open Access

Mapping intraoperative interictal epileptiform discharges using high‐resolution, thin‐film cortical arrays

Katrina J Barth iD, Iakov Rachinskiy, Suseendrakumar Duraivel, James Sun, Chia-Han Chiang, Charles Wang, Shervin Rahimpour, Michael M Haglund, Matthew Vestal, Stephen C Harward, Sasha Devore, Daniel Friedman und 7 weitere

Epilepsia · 2026-05 · 67 (5) · 2545-2558

DOI: 10.1002/epi.70135 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Epilepsia, online erschienen am 26.02.2026. Verfasst von Katrina J Barth und 18 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA. Hauptthemen laut MEDLINE: Electroencephalography, Epilepsy, Brain Mapping, Electrocorticography. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDCD NIH HHS, Department of Defense, NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Interictal epileptiform discharges (IEDs) are transients observed on the electroencephalogram (EEG) of patients with epilepsy. IEDs have traditionally been recorded from scalp or intracranial EEG macrocontacts, which coarsely sample neural activity. Here, we investigated the use of flexible, high‐resolution microelectrocorticographic (μECoG) arrays for measuring IEDs with greater spatiotemporal precision to test whether there exist microscale patterns of IED activity that may be missed on standard intracranial EEG.

Methods

We used liquid crystal polymer thin‐film μECoG arrays with both high resolution (.76–1.72‐mm spacing, 200‐μm diameter) and large cortical coverage (144–1596 mm 2 ) to record from seven patients undergoing surgical treatment of epilepsy. We identified IEDs by a combination of expert review and automated detection. We quantified the spatial extent of IEDs, mapped patterns of repeated IED activity, and quantified IED propagation direction using multilinear fit models. We also compared IED detection rates and propagation measurements between μECoG arrays and simulated macroarrays (10‐mm spacing, 2.3‐mm diameter).

Results

We demonstrated successful use of μECoG arrays to map intraoperative microscale patterns of IEDs. The majority of patients (5/7) exhibited elevated IED activity that was highly localized (subcentimeter localization). Across all patients, 40% of detected IEDs were observed within a 4‐mm radius of cortex. μECoG arrays also mapped the direction of IED propagation. An average of 39% (range = 4.2%–96.5%, SD = ±36.8%) of the IED events captured by the μECoG arrays were not detectable by simulated macrocontacts. Significance These intraoperative data demonstrate that μECoG arrays can map the microscale spatiotemporal activity of IEDs. These patterns of IEDs may be poorly captured by standard, macroscale recording devices. Our findings support the use of high‐resolution, large area coverage μECoG arrays for the presurgical and intraoperative mapping of epileptic cortex.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectroencephalographyEpilepsyBrain MappingElectrocorticographyCerebral CortexHumans

Stichwörter der Autor:innen

drug‐resistant epilepsyepilepsy surgeryinterictal epileptiform dischargesinterictal spikesintraoperative mappingmicroelectrocorticography

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA.
  • Center for Neural Science, New York University, New York, New York, USA.
  • Department of Neurosurgery, Clinical Neuroscience Center, University of Utah, Salt Lake City, Utah, USA.
  • Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah, USA.
  • Department of Neurosurgery, Duke University School of Medicine, Durham, North Carolina, USA.
  • Department of Neurology, New York University Grossman School of Medicine, New York, New York, USA.

ORCID-Profile: Katrina J Barth, Birgit Frauscher, Gregory B Cogan, Justin Blanco, Jonathan Viventi

Förderung

  • NIDCD NIH HHS
  • Department of Defense
  • NIH HHS
  • NINDS NIH HHS
  • Duke Clinical and Translational Science Institute
  • NIMH NIH HHS
  • Esther A. & Joseph Klingenstein Fund
  • National Science Foundation

Zitieren

APA

Barth, K. J., Rachinskiy, I., Duraivel, S., Sun, J., Chiang, C. H., Wang, C., Rahimpour, S., Haglund, M. M., Vestal, M., Harward, S. C., Devore, S., Friedman, D., Pesaran, B., Sinha, S. R., Southwell, D. G., Frauscher, B., Cogan, G. B., Blanco, J., & Viventi, J. (2026). Mapping intraoperative interictal epileptiform discharges using high‐resolution, thin‐film cortical arrays. Epilepsia, 67(5), 2545-2558. https://doi.org/10.1002/epi.70135

Vancouver

Barth KJ, Rachinskiy I, Duraivel S, Sun J, Chiang CH, Wang C, et al. Mapping intraoperative interictal epileptiform discharges using high‐resolution, thin‐film cortical arrays. Epilepsia. 2026;67(5):2545-2558. doi:10.1002/epi.70135

BibTeX
@article{Barth2026,
  author = {Barth, Katrina J and Rachinskiy, Iakov and Duraivel, Suseendrakumar and Sun, James and Chiang, Chia-Han and Wang, Charles and Rahimpour, Shervin and Haglund, Michael M and Vestal, Matthew and Harward, Stephen C and Devore, Sasha and Friedman, Daniel and Pesaran, Bijan and Sinha, Saurabh R and Southwell, Derek G and Frauscher, Birgit and Cogan, Gregory B and Blanco, Justin and Viventi, Jonathan},
  title = {Mapping intraoperative interictal epileptiform discharges using high‐resolution, thin‐film cortical arrays},
  journal = {Epilepsia},
  year = {2026},
  volume = {67},
  number = {5},
  pages = {2545--2558},
  doi = {10.1002/epi.70135}
}
Kostenlos starten →