EUVIMEDEUVIMED entdecken
Crossref

Lack of spontaneous typical seizures during intracranial monitoring with stereo‐electroencephalography

Juan S Bottan iD, Ashwaq Alshahrani, Greydon Gilmore, David A Steven, Jorge G Burneo iD, Jonathan C Lau iD, Richard S McLachlan, Andrew G Parrent, Keith W MacDougall, David C Diosy, Seyed M Mirsattari, Ana Suller Marti iD

Epileptic Disorders · 2023

DOI: 10.1002/epd2.20165 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Epileptic Disorders, 2023. Verfasst von Juan S Bottan und 11 weiteren Autor:innen. Beteiligte Einrichtung: Section of Neurosurgery, Hospital General de Niños "Pedro De Elizalde", Ciudad Autónoma de Buenos Aires, Argentina. Hauptthemen laut MEDLINE: Epilepsy, Drug Resistant Epilepsy. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

In the presurgical evaluation of patients with drug‐resistant epilepsy (DRE), occasionally, patients do not experience spontaneous typical seizures (STS) during a stereo‐electroencephalography (SEEG) study, which limits its effectiveness. We sought to identify risk factors for patients who did not have STS during SEEG and to analyze the clinical outcomes for this particular set of patients.

Methods

We conducted a retrospective analysis of all patients with DRE who underwent depth electrode implantation and SEEG recordings between January 2013 and December 2018.

Results

SEEG was performed in 155 cases during this period. 11 (7.2%) did not experience any clinical seizures (non‐STS group), while 143 experienced at least one patient‐typical seizure during admission (STS group). No significant differences were found between STS and non‐STS groups in terms of patient demographics, lesional/non‐lesional epilepsy ratio, pre‐SEEG seizure frequency, number of ASMs used, electrographic seizures or postoperative seizure outcome in those who underwent resective surgery. Statistically significant differences were found in the average number of electrodes implanted (7.0 in the non‐STS group vs. 10.2 in STS), days in Epilepsy Monitoring Unit (21.8 vs. 12.8 days) and the number of cases that underwent resective surgery following SEEG (27.3% vs. 60.8%), respectively. The three non‐STS patients (30%) who underwent surgery, all had their typical seizures triggered during ECS studies. Three cases were found to have psychogenic non‐epileptic seizures. None of the patients in the non‐STS group were offered neurostimulation devices. Five of the non‐STS patients experienced transient seizure improvement following SEEG. Significance We were unable to identify any factors that predicted lack of seizures during SEEG recordings. Resective surgery was only offered in cases where ECS studies replicated patient‐typical seizures. Larger datasets are required to be able to identify factors that predict which patients will fail to develop seizures during SEEG.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EpilepsyDrug Resistant EpilepsyHumansRetrospective StudiesTreatment OutcomeElectrodes, ImplantedSeizuresElectroencephalographyStereotaxic Techniques

Stichwörter der Autor:innen

absence of seizuresextra-operative cortical stimulationimplantation effectinsertional effectlack of seizuresstereo-electroencephalography

Autor:innen und Institutionen

  • Section of Neurosurgery, Hospital General de Niños "Pedro De Elizalde", Ciudad Autónoma de Buenos Aires, Argentina.
  • Department of Clinical Neurological Sciences, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada.
  • Department of Epidemiology & Biostatistics, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada.
  • Neuroepidemiology Unit, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada.
  • Department of Paediatrics, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada.

ORCID-Profile: Juan S Bottan, Jorge G Burneo, Jonathan C Lau, Ana Suller Marti

Zitieren

APA

Bottan, J. S., Alshahrani, A., Gilmore, G., Steven, D. A., Burneo, J. G., Lau, J. C., McLachlan, R. S., Parrent, A. G., MacDougall, K. W., Diosy, D. C., Mirsattari, S. M., & Suller Marti, A. (2023). Lack of spontaneous typical seizures during intracranial monitoring with stereo‐electroencephalography. Epileptic Disorders. https://doi.org/10.1002/epd2.20165

Vancouver

Bottan JS, Alshahrani A, Gilmore G, Steven DA, Burneo JG, Lau JC, et al. Lack of spontaneous typical seizures during intracranial monitoring with stereo‐electroencephalography. Epileptic Disorders. 2023. doi:10.1002/epd2.20165

BibTeX
@article{Bottan2023,
  author = {Bottan, Juan S and Alshahrani, Ashwaq and Gilmore, Greydon and Steven, David A and Burneo, Jorge G and Lau, Jonathan C and McLachlan, Richard S and Parrent, Andrew G and MacDougall, Keith W and Diosy, David C and Mirsattari, Seyed M and Suller Marti, Ana},
  title = {Lack of spontaneous typical seizures during intracranial monitoring with stereo‐electroencephalography},
  journal = {Epileptic Disorders},
  year = {2023},
  doi = {10.1002/epd2.20165}
}
Kostenlos starten →