EUVIMEDEUVIMED entdecken
Crossref

Experimental and thermodynamic investigation of a solar‐assisted lithium bromide–water single‐effect absorption cooling system with a flat‐plate collector: Energy, exergy, and thermo‐economic analysis

O. S. Khaleel, Muna Hassan Hussien, Ammar Hassan Soheel, Firas Aziz Ali, Ayad S. Abedalh

Environmental Progress & Sustainable Energy · 16.11.2026

DOI: 10.1002/ep.70684 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environmental Progress & Sustainable Energy, online erschienen am 16.11.2026. Verfasst von O. S. Khaleel und 4 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents an experimental, thermodynamic, exergy, and thermo‐economic investigation of a solar‐assisted single‐effect LiBr–H 2 O absorption cooling system integrated with a flat‐plate solar collector under the high‐solar‐irradiance conditions of Mosul, Iraq. Experimental measurements were performed under steady‐state operation, where the generator, condenser, absorber, and evaporator outlet temperatures reached 90°C, 35°C, 32°C, and 5°C, respectively. The system achieved a maximum experimental coefficient of performance (COP) of 0.75, demonstrating stable operation under realistic climatic conditions. Parametric analysis revealed that reducing both condenser and absorber temperatures by 5°C increased the COP by approximately 10%–12%, while the cooling capacity increased almost linearly for solar irradiance levels above 600 W/m 2 . Component‐level exergy analysis showed that the generator accounted for approximately 35% of the total exergy destruction, followed by the absorber (25%), identifying these components as the primary targets for performance enhancement. The uncertainty analysis indicated a maximum propagated COP uncertainty of ±4.1%, whereas statistical validation produced RMSE = 0.024 and MAPE = 3.2%, confirming excellent agreement between the thermodynamic model and experimental measurements. Thermo‐economic analysis predicted a simple payback period of 5–8 years, while the environmental assessment estimated an annual reduction of approximately 1.6 t CO 2 for a 5‐kW cooling system. Overall, the results demonstrate that solar‐assisted LiBr–H 2 O absorption cooling represents a technically reliable and environmentally sustainable cooling technology for hot‐arid regions, with considerable potential for further improvement through enhanced generator heat transfer and more effective heat‐rejection management.

Zitieren

APA

Khaleel, O. S., Hussien, M. H., Soheel, A. H., Ali, F. A., & Abedalh, A. S. (2026). Experimental and thermodynamic investigation of a solar‐assisted lithium bromide–water single‐effect absorption cooling system with a flat‐plate collector: Energy, exergy, and thermo‐economic analysis. Environmental Progress & Sustainable Energy. https://doi.org/10.1002/ep.70684

Vancouver

Khaleel OS, Hussien MH, Soheel AH, Ali FA, Abedalh AS. Experimental and thermodynamic investigation of a solar‐assisted lithium bromide–water single‐effect absorption cooling system with a flat‐plate collector: Energy, exergy, and thermo‐economic analysis. Environmental Progress & Sustainable Energy. 2026. doi:10.1002/ep.70684

BibTeX
@article{Khaleel2026,
  author = {Khaleel, O. S. and Hussien, Muna Hassan and Soheel, Ammar Hassan and Ali, Firas Aziz and Abedalh, Ayad S.},
  title = {Experimental and thermodynamic investigation of a solar‐assisted lithium bromide–water single‐effect absorption cooling system with a flat‐plate collector: Energy, exergy, and thermo‐economic analysis},
  journal = {Environmental Progress & Sustainable Energy},
  year = {2026},
  doi = {10.1002/ep.70684}
}
Kostenlos starten →