EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Multiphysics Modeling of Metronidazole Electroreduction at Polypyrrole/ ZIF ‐67 Porous Electrodes: Linking Porosity, Transport, and Kinetics

Rima Heider Al Omari, G. Padma Priya, Subhashree Ray, Talal Aziz Qassem, Gunjan Garg, Renu Sharma, Zokir Ataullaev, Rasul Usmanov, Naser Aslanian

Engineering Reports · 2026-11 · 8 (11)

DOI: 10.1002/eng2.71159 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Engineering Reports, online erschienen am 10.11.2026. Verfasst von Rima Heider Al Omari und 8 weiteren Autor:innen. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Understanding the coupling between porous architecture, molecular transport, and interfacial kinetics is essential for improving metronidazole (MNZ) electrochemical detection. This study investigates MNZ electroreduction at polypyrrole (PPy) nanotube/ZIF‐67‐modified electrodes using a two‐dimensional axisymmetric multiphysics framework incorporating transient diffusion, porous‐medium transport, and concentration‐dependent cathodic kinetics. The effective‐medium description incorporates accessible porosity and tortuosity, yielding a prescribed diffusivity dependence of D eff ∝ ε 2.5 . Porosity was varied from 0.2 to 0.8 to examine transport–reaction interactions under controlled operating conditions. The corrected analytical limiting‐current formulation predicts a 32‐fold increase in geometrically normalized current density across this interval, distinguishing constitutive transport scaling from coupled numerical behavior. Kinetic parameterization employed an effective charge‐transfer coefficient of 0.48 and reference exchange‐current densities within (0.8–1.4) × 10 −6 A cm −2 . Concentration‐dependent experimental comparisons were organized into calibration and validation conditions, with a reported maximum normalized root mean square error of 0.072. Sensitivity analysis identified porosity as the most influential parameter near the reference operating state, while finite perturbations revealed stronger interval‐dependent responses. The detection‐limit analysis was formulated using calibration sensitivity and a prescribed baseline‐noise standard deviation of 0.1 nA, providing conditional theoretical estimates rather than independently validated analytical detection limits. The findings establish a physically interpretable framework for assessing porous‐layer transport resistance, interfacial reactant availability, and potential‐dependent kinetic limitations in PPy/ZIF‐67‐based electrochemical sensing.

Zitieren

APA

Omari, R. H. A., Priya, G. P., Ray, S., Qassem, T. A., Garg, G., Sharma, R., Ataullaev, Z., Usmanov, R., & Aslanian, N. (2026). Multiphysics Modeling of Metronidazole Electroreduction at Polypyrrole/ ZIF ‐67 Porous Electrodes: Linking Porosity, Transport, and Kinetics. Engineering Reports, 8(11). https://doi.org/10.1002/eng2.71159

Vancouver

Omari RHA, Priya GP, Ray S, Qassem TA, Garg G, Sharma R, et al. Multiphysics Modeling of Metronidazole Electroreduction at Polypyrrole/ ZIF ‐67 Porous Electrodes: Linking Porosity, Transport, and Kinetics. Engineering Reports. 2026;8(11). doi:10.1002/eng2.71159

BibTeX
@article{Omari2026,
  author = {Omari, Rima Heider Al and Priya, G. Padma and Ray, Subhashree and Qassem, Talal Aziz and Garg, Gunjan and Sharma, Renu and Ataullaev, Zokir and Usmanov, Rasul and Aslanian, Naser},
  title = {Multiphysics Modeling of Metronidazole Electroreduction at Polypyrrole/ ZIF ‐67 Porous Electrodes: Linking Porosity, Transport, and Kinetics},
  journal = {Engineering Reports},
  year = {2026},
  volume = {8},
  number = {11},
  doi = {10.1002/eng2.71159}
}
Kostenlos starten →