EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Benchmark Response Values for Error‐Corrected Sequencing Mutagenicity Assessment Technologies

Saron Mulugeta, Francesco Marchetti iD, Guangchao Chen, Connie Chen, Raechel Puglisi, Paul A White iD

Environmental and Molecular Mutagenesis · 2026

DOI: 10.1002/em.70051 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environmental and Molecular Mutagenesis, 2026. Verfasst von Saron Mulugeta und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Computer Science, Carleton University, Ottawa, Ontario, Canada. Hauptthemen laut MEDLINE: Mutagens, Sequence Analysis, DNA. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Burroughs Wellcome Fund, Health Canada's Chemicals Management Plan, Genomics Research Development Initiative.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Benchmark Dose (BMD) approach is commonly used to determine Point‐of‐Departure (PoD) values for risk assessment and regulatory decision‐making; however, choosing a suitable Benchmark Response (BMR) for continuous endpoints is a challenge. Earlier work established a BMR of 50% for selected in vivo mutagenicity endpoints (i.e., Transgenic Rodent and Pig‐a ). Error‐corrected sequencing (ECS) technologies, such as Duplex Sequencing (DupSeq), Hawk‐Seq, PECC‐Seq, and PacBio HiFi, have emerged as powerful tools for mutagenicity assessment. This study applied and compared two approaches for defining BMR values for ECS technologies: the Effect Size (ES) theory of Slob (2017), and the one standard deviation approach of Zeller et al. (2017). A dose–response database of ECS studies was compiled to determine technology‐specific within‐group variance values ( var ) for BMR determination. Experimental factor influences on var , including species, rodent strain, administration route, application time, tissue type, tissue sampling time, and DNA fragmentation method, were examined; no significant influences were detected. The absence of covariate effects justified using typical, technology‐specific var values for BMR determinations. Using these values, technology‐specific BMRs were calculated as 27.7% for DupSeq, 16.6% for Hawk‐Seq, and 23.3% for PECC‐Seq. BMRs derived from negative control values were 22.6 to 28.8% for DupSeq, 5.6 to 13.8% for Hawk‐Seq, 28.7 to 31.5% for PECC‐Seq, and 9.5 to 22.8% for PacBio HiFi. These findings support adoption of a 30% BMR for in vivo ECS mutagenicity assessment technologies, providing a robust and consistent foundation for future dose–response modeling and human health risk assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MutagensSequence Analysis, DNAAnimalsMutagenicity TestsRisk AssessmentBenchmarkingDose-Response Relationship, Drug

Stichwörter der Autor:innen

HAWK‐seqPECC‐seqPROASTPacBio HiFibenchmark doseduplex sequencingeffect sizerisk assessment

Substanzen

Mutagens

Autor:innen und Institutionen

  • School of Computer Science, Carleton University, Ottawa, Ontario, Canada.
  • Environmental Health Science and Research Bureau, Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada.
  • Department of Biology, Carleton University, Ottawa, Ontario, Canada.
  • Centre for Prevention, Lifestyle and Health, RIVM (National Institute for Public Health and the Environment), Bilthoven, the Netherlands.
  • Health and Environmental Sciences Institute (HESI), Washington, DC, USA.

ORCID-Profile: Francesco Marchetti, Paul A White

Förderung

  • Burroughs Wellcome Fund
  • Health Canada's Chemicals Management Plan
  • Genomics Research Development Initiative

Zitieren

APA

Mulugeta, S., Marchetti, F., Chen, G., Chen, C., Puglisi, R., & White, P. A. (2026). Benchmark Response Values for Error‐Corrected Sequencing Mutagenicity Assessment Technologies. Environmental and Molecular Mutagenesis. https://doi.org/10.1002/em.70051

Vancouver

Mulugeta S, Marchetti F, Chen G, Chen C, Puglisi R, White PA. Benchmark Response Values for Error‐Corrected Sequencing Mutagenicity Assessment Technologies. Environmental and Molecular Mutagenesis. 2026. doi:10.1002/em.70051

BibTeX
@article{Mulugeta2026,
  author = {Mulugeta, Saron and Marchetti, Francesco and Chen, Guangchao and Chen, Connie and Puglisi, Raechel and White, Paul A},
  title = {Benchmark Response Values for Error‐Corrected Sequencing Mutagenicity Assessment Technologies},
  journal = {Environmental and Molecular Mutagenesis},
  year = {2026},
  doi = {10.1002/em.70051}
}
Kostenlos starten →