EUVIMEDEUVIMED entdecken
Crossref

Numerical Simulation Noise and Its Significant Impact on the Dielectrophoretic Motion of Particles Near the Electrode Edges

Aaditya Venkatesha Babu Bangaru, Stuart J Williams

ELECTROPHORESIS · 2025-08 · 46 (16) · 1221-1225

DOI: 10.1002/elps.8115 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ELECTROPHORESIS, online erschienen am 18.02.2025. Verfasst von Aaditya Venkatesha Babu Bangaru und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, University of Louisville, Louisville, Kentucky, USA. Hauptthemen laut MEDLINE: Electrophoresis, Models, Theoretical. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Dielectrophoresis (DEP) has been extensively researched over the years for filtration, separation, detection, and collection of micro/nano/bioparticles. Numerical models have historically been employed to predict particle trajectories in three‐dimensional (3D) DEP systems, but a common issue arises due to inherent noise near the edges of electrodes due to electric potential discontinuity, specifically when calculating electric field and gradient of electric field‐squared, . This noise can be reduced to a certain extent with a finer mesh density but results near the electrode edge still have significant error. Realizing the importance of particle‐electrode edge interactions prevalent in positive DEP systems, analytical solutions given by Sun et al. was incorporated to demonstrate an improved 3D model of interdigitated electrodes. The results of electric field and gradient of electric field‐squared of the numerical model and the improved analytical 3D model were compared, within a simulation space of 50 µm height, 10 µm width, and 50 µm length with interdigitated electrodes of the same width and gap of 10 µm. The DEP particle trajectory error due to the noise was quantified for different particle sizes at various heights above the electrode edge. For example, at 5 V rms , a trapped 500 nm particles exhibited a velocity error of 10 4 µm/s (it should have been zero).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrophoresisModels, TheoreticalElectrodesComputer SimulationParticle SizeMotion

Autor:innen und Institutionen

  • Department of Mechanical Engineering, University of Louisville, Louisville, Kentucky, USA.

Zitieren

APA

Bangaru, A. V. B., & Williams, S. J. (2025). Numerical Simulation Noise and Its Significant Impact on the Dielectrophoretic Motion of Particles Near the Electrode Edges. ELECTROPHORESIS, 46(16), 1221-1225. https://doi.org/10.1002/elps.8115

Vancouver

Bangaru AVB, Williams SJ. Numerical Simulation Noise and Its Significant Impact on the Dielectrophoretic Motion of Particles Near the Electrode Edges. ELECTROPHORESIS. 2025;46(16):1221-1225. doi:10.1002/elps.8115

BibTeX
@article{Bangaru2025,
  author = {Bangaru, Aaditya Venkatesha Babu and Williams, Stuart J},
  title = {Numerical Simulation Noise and Its Significant Impact on the Dielectrophoretic Motion of Particles Near the Electrode Edges},
  journal = {ELECTROPHORESIS},
  year = {2025},
  volume = {46},
  number = {16},
  pages = {1221--1225},
  doi = {10.1002/elps.8115}
}