EUVIMEDEUVIMED entdecken
Crossref

A Wavelet‐ALS‐Assisted CNN–BiGRU Method for Peak Recognition in CCD‐Based Capillary Electrophoresis Fluorescence Detection

Liwei Xue, Jiajun Ma, Gejiang Wan, Bin Long, Yimin Mao, Fangtian Wang, Shicai Bai

ELECTROPHORESIS · 03.11.2026

DOI: 10.1002/elps.70177 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ELECTROPHORESIS, online erschienen am 03.11.2026. Verfasst von Liwei Xue und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Big Data and Information Engineering, Guizhou University, Guiyang, Guizhou, China. Die Arbeit nennt 26 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Capillary electrophoresis (CE) is an efficient, rapid, and sensitive separation and analysis technique that has been widely applied in biochemistry, pharmaceutical research, and environmental monitoring. However, charge‐coupled device (CCD)‐based CE fluorescence signals are susceptible to baseline drift, random noise, and channel crosstalk, which reduce the accuracy of peak recognition. To meet the demand for high‐precision signal analysis, this study proposes a convolutional neural network (CNN)–bidirectional gated recurrent unit (BiGRU) peak recognition algorithm on the basis of wavelet transform and one‐dimensional asymmetric least squares (ALS). In the proposed system, an FPGA‐based platform is used for real‐time signal acquisition and data transmission, whereas the host computer performs subsequent processing of the received spectral data. Experimental results show that the proposed method achieves high‐accuracy peak recognition on the spectral dataset, with Precision, Recall, and F 1‐score reaching 98.44%, 99.93%, and 99.18%, respectively. These results demonstrate its good robustness and practical applicability, providing technical support for the miniaturization and intelligent development of portable gene sequencers.

Schlagwörter

Stichwörter der Autor:innen

CNN–BiGRUFPGAasymmetric least squaresbaseline correctioncapillary electrophoresisfluorescence signalpeak recognitionportable gene sequencerwavelet transform

Autor:innen und Institutionen

  • School of Big Data and Information Engineering, Guizhou University, Guiyang, Guizhou, China.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Xue, L., Ma, J., Wan, G., Long, B., Mao, Y., Wang, F., & Bai, S. (2026). A Wavelet‐ALS‐Assisted CNN–BiGRU Method for Peak Recognition in CCD‐Based Capillary Electrophoresis Fluorescence Detection. ELECTROPHORESIS. https://doi.org/10.1002/elps.70177

Vancouver

Xue L, Ma J, Wan G, Long B, Mao Y, Wang F, et al. A Wavelet‐ALS‐Assisted CNN–BiGRU Method for Peak Recognition in CCD‐Based Capillary Electrophoresis Fluorescence Detection. ELECTROPHORESIS. 2026. doi:10.1002/elps.70177

BibTeX
@article{Xue2026,
  author = {Xue, Liwei and Ma, Jiajun and Wan, Gejiang and Long, Bin and Mao, Yimin and Wang, Fangtian and Bai, Shicai},
  title = {A Wavelet‐ALS‐Assisted CNN–BiGRU Method for Peak Recognition in CCD‐Based Capillary Electrophoresis Fluorescence Detection},
  journal = {ELECTROPHORESIS},
  year = {2026},
  doi = {10.1002/elps.70177}
}
Kostenlos starten →