EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Determination of Flunixin Meglumine in Veterinary Pharmaceutical Formulations by Capillary Electrophoresis With Capacitively Coupled Contactless Conductivity Detection

Letícia M de Araujo, José A Fracassi da Silva, Dosil P de Jesus

ELECTROPHORESIS · 2026-08 · 47 (8) · 690-695

DOI: 10.1002/elps.70114 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ELECTROPHORESIS, online erschienen am 23.05.2026. Verfasst von Letícia M de Araujo und 2 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Chemistry, Universidade Estadual de Campinas (UNICAMP), Campinas, São Paulo, Brazil. Hauptthemen laut MEDLINE: Veterinary Drugs, Clonixin. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Brazilian National Council for Scientific and Technological Development.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This work describes a novel, simple, fast, reliable, and environmentally friendly analytical method for the determination of the anti‐inflammatory and analgesic drug flunixin meglumine (FM) in veterinary pharmaceutical formulations. The method uses capillary electrophoresis with capacitively coupled contactless conductivity detection (CE‐C 4 D) to quantify meglumine ( N ‐methylglucamine), the counterion of flunixin in FM. This approach allows the use of the less expensive and more readily available meglumine, rather than FM or flunixin, as the standard reagent. Lithium ions were used as an internal standard, and the migration time of the meglumine was 2.2 min using a capillary with a total length of 50 cm (42 cm effective) and 50 µm (i.d.), filled with a background electrolyte (BGE) composed of 2‐( N ‐morpholino)ethanesulfonic acid (MES) and histidine (His), each at 20 mmol L −1 . Good linearity was attained ( R 2 = 0.992) in a concentration range of 100–2500 µg mL −1 . The limits of detection (LOD) and quantification (LOQ) were calculated as 22.7 and 75.6 µg mL −1 , respectively. The accuracy of the method was assessed using recovery tests at three concentration levels, resulting in recoveries ranging from 89% to 104%. The intra‐ and inter‐day precisions ranged from 2.3% to 4.2%. The proposed CE‐C 4 D was successfully applied to determine FM in commercial veterinary formulations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Veterinary DrugsClonixinElectrophoresis, CapillaryLimit of DetectionReproducibility of ResultsElectric ConductivityLinear ModelsAnimals

Stichwörter der Autor:innen

electrochemical detectionelectromigrationpharmaceutical analysisveterinary drugs

Substanzen

Veterinary DrugsClonixinflunixin meglumine

Autor:innen und Institutionen

  • Institute of Chemistry, Universidade Estadual de Campinas (UNICAMP), Campinas, São Paulo, Brazil.
  • National Institute of Science and Technology of Bioanalytics Lauro Kubota (INCTBio-LK), Institute of Chemistry, Universidade Estadual de Campinas (UNICAMP), Campinas, São Paulo, Brazil.

Förderung

  • Brazilian National Council for Scientific and Technological Development

Zitieren

APA

de Araujo, L. M., da Silva, J. A. F., & de Jesus, D. P. (2026). Determination of Flunixin Meglumine in Veterinary Pharmaceutical Formulations by Capillary Electrophoresis With Capacitively Coupled Contactless Conductivity Detection. ELECTROPHORESIS, 47(8), 690-695. https://doi.org/10.1002/elps.70114

Vancouver

de Araujo LM, da Silva JAF, de Jesus DP. Determination of Flunixin Meglumine in Veterinary Pharmaceutical Formulations by Capillary Electrophoresis With Capacitively Coupled Contactless Conductivity Detection. ELECTROPHORESIS. 2026;47(8):690-695. doi:10.1002/elps.70114

BibTeX
@article{deAraujo2026,
  author = {de Araujo, Letícia M and da Silva, José A Fracassi and de Jesus, Dosil P},
  title = {Determination of Flunixin Meglumine in Veterinary Pharmaceutical Formulations by Capillary Electrophoresis With Capacitively Coupled Contactless Conductivity Detection},
  journal = {ELECTROPHORESIS},
  year = {2026},
  volume = {47},
  number = {8},
  pages = {690--695},
  doi = {10.1002/elps.70114}
}
Kostenlos starten →