Enhanced Particle Trap: Design and Simulation of Pillar‐Based Contactless Dielectrophoresis Microfluidic Devices
ELECTROPHORESIS · 2025-02 · 46 (3-4) · 232-239
DOI: 10.1002/elps.202400110 ↗Kurz gefasst
Fachartikel in der Zeitschrift ELECTROPHORESIS, online erschienen am 18.02.2025. Verfasst von Peyman Torky Harchegani und 3 weiteren Autor:innen. Beteiligte Einrichtung: Small Medical Devices, Bio-MEMS & LoC Lab, School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran. Hauptthemen laut MEDLINE: Electrophoresis, Cell Separation, Lab-On-A-Chip Devices, Microfluidic Analytical Techniques. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 42 Literaturangaben.
Abstract (Originalsprache)
Contactless and conventional dielectrophoresis (DEP) microfluidic devices are extensively utilized in lab‐on‐a‐chip applications, particularly for cell isolation and analysis. Nonetheless, these devices typically operate at low throughput and require high applied voltages, posing limitations for microfluidic cell isolation and separation. Addressing these challenges, this study explores the utilization of diverse micro‐pillar geometries within the microfluidic device to augment THP‐1 cell trapping efficiency numerically using FEM modeling. Furthermore, the simulations examine the influence of pillar gap and quantity on cell trapping efficiency in a contactless DEP device. Notably, elliptical pillars demonstrate superior cell trapping efficiency at elevated flow rates compared to alternative configurations, making the microchip more amenable for high‐throughput cell separation, trapping, and isolation applications. Remarkably, employing elliptical pillars in a contactless DEP microfluidic chip yields nearly 100% cell trapping efficiency at higher flow rates. Ellipse configuration showed 122% higher cell trap efficiency at the maximum flowrate compare to the previous study with circular configuration. Additionally, it is observed that reducing the gap between pillars correlates with enhanced cell trapping efficiency. Simulation outcomes indicate that employing two rows of elliptical pillars with a 40‐µm gap achieves optimal performance. The findings of this investigation underscore the importance of pillars in contactless DEP devices and provide valuable insights for future designs of such microfluidic devices.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Small Medical Devices, Bio-MEMS & LoC Lab, School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran.
- Department of Molecular Medicine, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran.
Zitieren
APA
Torky Harchegani, P., Mashhadi Keshtiban, M., Moghimi Zand, M., & Azizi, Z. (2025). Enhanced Particle Trap: Design and Simulation of Pillar‐Based Contactless Dielectrophoresis Microfluidic Devices. ELECTROPHORESIS, 46(3-4), 232-239. https://doi.org/10.1002/elps.202400110
Vancouver
Torky Harchegani P, Mashhadi Keshtiban M, Moghimi Zand M, Azizi Z. Enhanced Particle Trap: Design and Simulation of Pillar‐Based Contactless Dielectrophoresis Microfluidic Devices. ELECTROPHORESIS. 2025;46(3-4):232-239. doi:10.1002/elps.202400110
BibTeX
@article{TorkyHarchegani2025,
author = {Torky Harchegani, Peyman and Mashhadi Keshtiban, Mohsen and Moghimi Zand, Mahdi and Azizi, Zahra},
title = {Enhanced Particle Trap: Design and Simulation of Pillar‐Based Contactless Dielectrophoresis Microfluidic Devices},
journal = {ELECTROPHORESIS},
year = {2025},
volume = {46},
number = {3-4},
pages = {232--239},
doi = {10.1002/elps.202400110}
}