Imaged Capillary Isoelectric Focusing Coupled to High‐Resolution Mass Spectrometry (icIEF‐MS) for Cysteine‐Linked Antibody–Drug Conjugate (ADC) Heterogeneity Characterization Under Native Condition
ELECTROPHORESIS · 2024
DOI: 10.1002/elps.202400083 ↗Kurz gefasst
Fachartikel in der Zeitschrift ELECTROPHORESIS, 2024. Verfasst von Xiaoxi Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Thermo Fisher Scientific, Shanghai, China. Hauptthemen laut MEDLINE: Immunoconjugates, Cysteine, Isoelectric Focusing, Electrophoresis, Capillary. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: Federal Economic Development Agency.
Abstract (Originalsprache)
Native mass spectrometry (nMS) is a cutting‐edge technique that leverages electrospray ionization MS (ESI‐MS) to investigate large biomolecules and their complexes in solution. The goal of nMS is to retain the native structural features and interactions of the analytes during the transition to the gas phase, providing insights into their natural conformations. In biopharmaceutical development, nMS serves as a powerful tool for analyzing complex protein heterogeneity, allowing for the examination of non‐covalently bonded assemblies in a state that closely resembles their natural folded form. Herein, we present an imaged capillary isoelectric focusing–MS (icIEF–MS) workflow to characterize cysteine‐linked antibody–drug conjugate (ADC) under native conditions. Two ADCs were analyzed: a latest generation cysteine‐linked ADC polatuzumab vedotin and the first FDA‐approved cysteine‐linked ADC brentuximab vedotin. This workflow benefits from a recently developed icIEF system that is MS‐friendly and capable of directly coupling to a high‐sensitivity MS instrument. Results show that the icIEF separation is influenced by both drug payloads and the post‐translational modifications (PTMs), which are then promptly identified by MS. Overall, this native icIEF–MS method demonstrates the potential to understand and control the critical quality attributes (CQAs) that are essential for the safe and effective use of ADCs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Thermo Fisher Scientific, Shanghai, China.
- Key Laboratory of the Ministry of Health for Research on Quality and Standardization of Biotech Products, National Institutes for Food and Drug Control, Beijing, China.
- Thermo Fisher Scientific, Lexington, Massachusetts, USA.
- Advanced Electrophoresis Solutions LTD, Cambridge, Ontario, Canada.
ORCID-Profile: Xiaoxi Zhang, Gang Wu
Förderung
- Federal Economic Development Agency
Zitieren
APA
Zhang, X., Wu, G., Du, M., Bo, T., Chen, T., & Huang, T. (2024). Imaged Capillary Isoelectric Focusing Coupled to High‐Resolution Mass Spectrometry (icIEF‐MS) for Cysteine‐Linked Antibody–Drug Conjugate (ADC) Heterogeneity Characterization Under Native Condition. ELECTROPHORESIS. https://doi.org/10.1002/elps.202400083
Vancouver
Zhang X, Wu G, Du M, Bo T, Chen T, Huang T. Imaged Capillary Isoelectric Focusing Coupled to High‐Resolution Mass Spectrometry (icIEF‐MS) for Cysteine‐Linked Antibody–Drug Conjugate (ADC) Heterogeneity Characterization Under Native Condition. ELECTROPHORESIS. 2024. doi:10.1002/elps.202400083
BibTeX
@article{Zhang2024,
author = {Zhang, Xiaoxi and Wu, Gang and Du, Min and Bo, Tao and Chen, Tong and Huang, Tiemin},
title = {Imaged Capillary Isoelectric Focusing Coupled to High‐Resolution Mass Spectrometry (icIEF‐MS) for Cysteine‐Linked Antibody–Drug Conjugate (ADC) Heterogeneity Characterization Under Native Condition},
journal = {ELECTROPHORESIS},
year = {2024},
doi = {10.1002/elps.202400083}
}
EUVIMED