EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Surfactant‐Based Polymer Microchip Electrophoresis of Ciprofloxacin Hydrochloride Monohydrate in Unfiltered Milk With Fluorescence Detection

Camille A Leclerc, Christopher G D Ty, Sean S Worthington, Malley B Richardson, Abdulla K AlSawalhi, Larry Wood, Khalid Moomand, Christopher M Collier

ELECTROPHORESIS · 2025

DOI: 10.1002/elps.202400079 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ELECTROPHORESIS, 2025. Verfasst von Camille A Leclerc und 7 weiteren Autor:innen. Beteiligte Einrichtung: Collier Research Group, School of Engineering, The University of British Columbia, Kelowna, British Columbia, Canada. Hauptthemen laut MEDLINE: Milk, Ciprofloxacin, Electrophoresis, Microchip, Surface-Active Agents. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, NSERC Alliance.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This work describes a cross‐shaped PMMA ME system capable of detecting ciprofloxacin hydrochloride monohydrate (CPFH) in unfiltered milk samples. The cross‐shaped PMMA ME system utilizes a BGE consisting primarily of the surface‐active agent SDS to solubilize milk fat and improve the zeta potential of the PMMA microchannel surface. A theoretical lumped‐element circuit model for cross‐shaped ME is introduced in this work to calculate the migration time of CPFH. This manuscript improves the capabilities of PMMA‐based ME for CPFH in milk using an SDS‐based BGE. The presented ME system has a faster migration time, higher mean output voltage, and thinner full‐width at half‐maximum than previously reported dairy‐based biosensor systems. Most notably, the migration time of the new system is under 10 min, being the time associated with the milking of cattle. The system is also found to be able to detect the presence of milk fat. Discussion is included of potential future integration with existing high‐sensitivity methodologies to place the overall ME system's limit of detection below an established target. To the authors’ knowledge, this is the first reported account of a PMMA ME system capable of detecting CPFH in unfiltered milk.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MilkCiprofloxacinElectrophoresis, MicrochipSurface-Active AgentsAnimalsPolymethyl MethacrylateCattleLimit of Detection

Stichwörter der Autor:innen

PMMAantibiotic detectionmicrochip electrophoresismilk

Substanzen

CiprofloxacinSurface-Active AgentsPolymethyl Methacrylate

Autor:innen und Institutionen

  • Collier Research Group, School of Engineering, The University of British Columbia, Kelowna, British Columbia, Canada.
  • CG Wellington, Drayton, Ontario, Canada.
  • Agrisan Specialty Chemical and Pharmaceutical, Arthur, Ontario, Canada.

Förderung

  • Natural Sciences and Engineering Research Council of Canada
  • NSERC Alliance

Zitieren

APA

Leclerc, C. A., Ty, C. G. D., Worthington, S. S., Richardson, M. B., AlSawalhi, A. K., Wood, L., Moomand, K., & Collier, C. M. (2025). Surfactant‐Based Polymer Microchip Electrophoresis of Ciprofloxacin Hydrochloride Monohydrate in Unfiltered Milk With Fluorescence Detection. ELECTROPHORESIS. https://doi.org/10.1002/elps.202400079

Vancouver

Leclerc CA, Ty CGD, Worthington SS, Richardson MB, AlSawalhi AK, Wood L, et al. Surfactant‐Based Polymer Microchip Electrophoresis of Ciprofloxacin Hydrochloride Monohydrate in Unfiltered Milk With Fluorescence Detection. ELECTROPHORESIS. 2025. doi:10.1002/elps.202400079

BibTeX
@article{Leclerc2025,
  author = {Leclerc, Camille A and Ty, Christopher G D and Worthington, Sean S and Richardson, Malley B and AlSawalhi, Abdulla K and Wood, Larry and Moomand, Khalid and Collier, Christopher M},
  title = {Surfactant‐Based Polymer Microchip Electrophoresis of Ciprofloxacin Hydrochloride Monohydrate in Unfiltered Milk With Fluorescence Detection},
  journal = {ELECTROPHORESIS},
  year = {2025},
  doi = {10.1002/elps.202400079}
}
Kostenlos starten →