EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparative analysis of plasma affinity depletion methods: Impact on protein composition and phosphopeptide abundance in human plasma

Pallaprolu Nikhil, Dande Aishwarya, Sameer Dhingra, Krishna Pandey, V Ravichandiran, Ramalingam Peraman iD

ELECTROPHORESIS · 2024

DOI: 10.1002/elps.202400030 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift ELECTROPHORESIS, 2024. Verfasst von Pallaprolu Nikhil und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical Analysis, National Institute of Pharmaceutical Education and Research, Hajipur, Bihar, India. Hauptthemen laut MEDLINE: Phosphopeptides, Blood Proteins, Proteomics. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Affinity‐based protein depletion and TiO 2 enrichment methods play a crucial role in detection of low‐abundant proteins and phosphopeptides enrichment, respectively. Here, we assessed the effectiveness of HSA/IgG (HU2) and Human 7 (HU7) depletion methods and their impact on phosphopeptides coverage through comparative proteome analysis, utilizing in‐solution digestion and nano‐LC‐Orbitrap mass spectrometry (MS). Our results demonstrated that both HU2 and HU7 affinity depletion significantly decreased high‐abundant proteins by 1.5–7.8‐fold ( p < 0.001). A total of 1491 proteins were identified, with 48 proteins showing significant expression in the depleted groups. Notably, cadherin‐13, neutrophil defensin 1, APM1, and desmoplakin variant protein were exclusively detected in the HU2/HU7‐depleted groups. Furthermore, study on effect of depletion on phosphopeptides revealed an increase in tandem MS spectral counts with notable decrease (∼50%) in peptide spectrum matching in depleted groups, which was attributed to significant reduction in protein counts. Our post translation modification workflow for phosphoproteomics detected 42 phosphorylated peptides, corresponding to 12 phosphoproteins with unique peptide match ≥2 (high false discovery rates confidence). Among them, 10 phosphorylated proteins are highly expressed in depleted groups. Overall, these findings offer valuable insights in selection of protein depletion methods for comprehensive plasma proteomics analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhosphopeptidesBlood ProteinsProteomicsHumansTandem Mass SpectrometryChromatography, LiquidProteomeChromatography, AffinityPhosphoproteins

Stichwörter der Autor:innen

LC‐Orbitrap‐MSpeptide enrichmentphosphoproteomicsplasma affinity depletion

Substanzen

PhosphopeptidesBlood ProteinsProteomePhosphoproteins

Autor:innen und Institutionen

  • Department of Pharmaceutical Analysis, National Institute of Pharmaceutical Education and Research, Hajipur, Bihar, India.
  • Department of Pharmacy Practice, National Institute of Pharmaceutical Education and Research, Hajipur, Bihar, India.
  • Division of Clinical Medicine, Rajendra Memorial Research Institute of Medical Sciences, Patna, Bihar, India.

ORCID-Profile: Ramalingam Peraman

Zitieren

APA

Nikhil, P., Aishwarya, D., Dhingra, S., Pandey, K., Ravichandiran, V., & Peraman, R. (2024). Comparative analysis of plasma affinity depletion methods: Impact on protein composition and phosphopeptide abundance in human plasma. ELECTROPHORESIS. https://doi.org/10.1002/elps.202400030

Vancouver

Nikhil P, Aishwarya D, Dhingra S, Pandey K, Ravichandiran V, Peraman R. Comparative analysis of plasma affinity depletion methods: Impact on protein composition and phosphopeptide abundance in human plasma. ELECTROPHORESIS. 2024. doi:10.1002/elps.202400030

BibTeX
@article{Nikhil2024,
  author = {Nikhil, Pallaprolu and Aishwarya, Dande and Dhingra, Sameer and Pandey, Krishna and Ravichandiran, V and Peraman, Ramalingam},
  title = {Comparative analysis of plasma affinity depletion methods: Impact on protein composition and phosphopeptide abundance in human plasma},
  journal = {ELECTROPHORESIS},
  year = {2024},
  doi = {10.1002/elps.202400030}
}
Kostenlos starten →