A dual‐reference study design for understanding and improving AAV genome size analysis
ELECTROPHORESIS · 2024
DOI: 10.1002/elps.202400011 ↗Kurz gefasst
Fachartikel in der Zeitschrift ELECTROPHORESIS, 2024. Verfasst von Yali Sun und 7 weiteren Autor:innen. Beteiligte Einrichtung: Revvity, Inc, Waltham, Massachusetts, USA. Hauptthemen laut MEDLINE: Dependovirus, DNA, Single-Stranded, Genome, Viral, Electrophoresis, Capillary. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Revvity, Inc.
Abstract (Originalsprache)
Recombinant adeno‐associated virus (rAAV) is the leading platform of gene delivery for its long‐lasting gene transformation and low immunogenicity. Characterization of the integrity and purity of the rAAV genome is critical to ensure clinical potency and safety. However, current rAAV genome characterization methods that can provide size assessment are either time‐consuming or not easily accessible to general labs. Additionally, there is a lack of right reference standard for analyzing long single‐stranded DNA (ssDNA) fragments. Here, we have developed an ssDNA assay on a microfluidic capillary electrophoresis platform using ssDNA reference standard. This assay provides size calling for ssDNA fragment, a detection sensitivity at ∼89 pg/µL (3 × 10 10 GC/mL AAV) for 5.1 kb ssDNA fragment, and a turnaround time at ∼100 s per sample with a high throughput sample analyzing capability. Moreover, we have observed that the annealing of AAV ssDNA subsequent to its release from the capsid might introduce an additional double‐stranded DNA (dsDNA) peak. This phenomenon is dependent on the sample processing workflow. To avoid the risk of mischaracterization, we recommend the use of dual‐reference standards in combination with other orthogonal methods to have a comprehensive understanding of the rAAV genome size and integrity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Revvity, Inc, Waltham, Massachusetts, USA.
ORCID-Profile: Yali Sun, Zhi-Xiang Lu, Michael Miller, Yanhong Tong
Förderung
- Revvity, Inc
Zitieren
APA
Sun, Y., Lu, Z. X., Miller, M., Valcour, Y., Khimani, A. H., Bauer, J., Salomon, M., & Tong, Y. (2024). A dual‐reference study design for understanding and improving AAV genome size analysis. ELECTROPHORESIS. https://doi.org/10.1002/elps.202400011
Vancouver
Sun Y, Lu ZX, Miller M, Valcour Y, Khimani AH, Bauer J, et al. A dual‐reference study design for understanding and improving AAV genome size analysis. ELECTROPHORESIS. 2024. doi:10.1002/elps.202400011
BibTeX
@article{Sun2024,
author = {Sun, Yali and Lu, Zhi-Xiang and Miller, Michael and Valcour, Ying and Khimani, Anis H and Bauer, Jana and Salomon, Michael and Tong, Yanhong},
title = {A dual‐reference study design for understanding and improving AAV genome size analysis},
journal = {ELECTROPHORESIS},
year = {2024},
doi = {10.1002/elps.202400011}
}
EUVIMED