EUVIMEDEUVIMED entdecken
Open Access

Suppressing the background of LC–ESI–MS analysis of permethylated glycans using the active background ion reduction device

Mojibola Fowowe iD, Aiying Yu, Junyao Wang, Sherifdeen Onigbinde iD, Judith Nwaiwu iD, Andrew I Bennett iD, Yehia Mechref iD

ELECTROPHORESIS · 2024

DOI: 10.1002/elps.202300301 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ELECTROPHORESIS, 2024. Verfasst von Mojibola Fowowe und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas, USA. Hauptthemen laut MEDLINE: Spectrometry, Mass, Electrospray Ionization, Polysaccharides. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS, Robert A. Welch Foundation, NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Mass spectrometry (MS) has revolutionized analytical chemistry, enabling precise identification and quantification of chemical species, which is pivotal for biomarker discovery and understanding complex biological systems. Despite its versatility, the presence of background ions in MS analysis hinders the sensitive detection of low‐abundance analytes. Therefore, studies aimed at lowering background ion levels have become increasingly important. Here, we utilized the commercially available Active Background Ion Reduction Device (ABIRD) to suppress background ions and assess its effect on the liquid chromatography–electrospray ionization (LC–ESI)–MS analyses of N ‐glycans on the Q Exactive HF mass spectrometer. We also investigated the effect of different solvent vapors in the ESI source on N ‐glycan analysis by MS. ABIRD generally had no effect on high‐mannose and neutral structures but reduced the intensity of some structures that contained sialic acid, fucose, or both when methanol vapor filled the ESI source. Based on our findings on the highest number of identified N ‐glycans from human serum, methanol vapor in the ion source compartment may enhance N ‐glycan LC–ESI–MS analyses by improving the desolvation of droplets formed during the ESI process due to its high volatility. This protocol may be further validated and extended to advanced bottom‐up proteomic/glycoproteomic studies for the analysis of peptide/glycopeptide ions by MS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spectrometry, Mass, Electrospray IonizationPolysaccharidesHumansChromatography, LiquidMethylationMethanolIonsEquipment Design

Stichwörter der Autor:innen

ABIRDLC–ESI–MSN‐glycansbackground ion reductionglycomics

Substanzen

PolysaccharidesMethanolIons

Autor:innen und Institutionen

  • Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas, USA.

ORCID-Profile: Mojibola Fowowe, Sherifdeen Onigbinde, Judith Nwaiwu, Andrew I Bennett, Yehia Mechref

Förderung

  • NIGMS NIH HHS
  • Robert A. Welch Foundation
  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Fowowe, M., Yu, A., Wang, J., Onigbinde, S., Nwaiwu, J., Bennett, A. I., & Mechref, Y. (2024). Suppressing the background of LC–ESI–MS analysis of permethylated glycans using the active background ion reduction device. ELECTROPHORESIS. https://doi.org/10.1002/elps.202300301

Vancouver

Fowowe M, Yu A, Wang J, Onigbinde S, Nwaiwu J, Bennett AI, et al. Suppressing the background of LC–ESI–MS analysis of permethylated glycans using the active background ion reduction device. ELECTROPHORESIS. 2024. doi:10.1002/elps.202300301

BibTeX
@article{Fowowe2024,
  author = {Fowowe, Mojibola and Yu, Aiying and Wang, Junyao and Onigbinde, Sherifdeen and Nwaiwu, Judith and Bennett, Andrew I and Mechref, Yehia},
  title = {Suppressing the background of LC–ESI–MS analysis of permethylated glycans using the active background ion reduction device},
  journal = {ELECTROPHORESIS},
  year = {2024},
  doi = {10.1002/elps.202300301}
}
Kostenlos starten →