EUVIMEDEUVIMED entdecken
Crossref

Development of an easy‐to‐set‐up multiple heart‐cutting achiral–chiral LC–LC method for the analysis of branched‐chain amino acids in commercial tablets

Ina Varfaj, Ghaid W A Abualzulof, Simone Moretti, Anna Migni, Irene Uda, Laura Goracci, Federica Ianni, Andrea Carotti, Roccaldo Sardella iD

ELECTROPHORESIS · 2024

DOI: 10.1002/elps.202300278 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ELECTROPHORESIS, 2024. Verfasst von Ina Varfaj und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical Sciences, University of Perugia, Perugia, Italy. Hauptthemen laut MEDLINE: Tablets, Amino Acids, Branched-Chain. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 55 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this paper, the development and application of a multiple heart‐cutting achiral–chiral LC–LC method (mLC–LC) for the analysis of dansylated (Dns) branched‐chain amino acids in commercial tablets are described. In the first dimension, a Waters Xbridge RP C18 achiral column was used under gradient conditions with buffered aqueous solution and acetonitrile. The elution order Dns‐valine (Dns‐Val) < Dns‐isoleucine (Dns‐Ile) < Dns‐leucine (Dns‐Leu) turned out with full resolution between adjacent peaks: 7.25 and 1.50 for the Val/Ile and the Ile/Leu pairs, respectively. A “research” validation study was performed, revealing high accuracy (Recovery%) and precision (RSD%) using two external set solutions, respectively, in the range 93.7%–104.1% and 0.4%–3.2%. The C18 column was connected via a two‐position six‐port switching valve to the quinidine‐based Chiralpak quinidine‐anion‐exchange chiral column. A water/acetonitrile, 30/70 (v/v) with 50 mM ammonium acetate (apparent pH of 5.5) eluent allowed getting the three enantiomers’ pairs resolved: R S equal to 4.3 for Dns‐Val and Dns‐Ile, and 1.7 for Dns‐Leu. The application of the mLC‐LC method confirmed that the content of Val, Ile, and Leu in the tablets was compliant with that labeled by the producer. Only l ‐enantiomers were found in the food supplement, as confirmed by LC–MS/MS analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TabletsAmino Acids, Branched-ChainStereoisomerismChromatography, LiquidReproducibility of ResultsDansyl CompoundsTandem Mass SpectrometryLinear Models

Stichwörter der Autor:innen

branched‐chain amino acidsfood supplementmultiple heart‐cutting two‐dimensional chromatographyquality controlquinidine‐based chiral selector

Substanzen

TabletsAmino Acids, Branched-ChainDansyl Compounds

Autor:innen und Institutionen

  • Department of Pharmaceutical Sciences, University of Perugia, Perugia, Italy.
  • Molecular Horizon, Bettona, Perugia, Italy.
  • Department of Chemistry, Biology and Biotechnology, University of Perugia, Perugia, Italy.

ORCID-Profile: Roccaldo Sardella

Zitieren

APA

Varfaj, I., Abualzulof, G. W. A., Moretti, S., Migni, A., Uda, I., Goracci, L., Ianni, F., Carotti, A., & Sardella, R. (2024). Development of an easy‐to‐set‐up multiple heart‐cutting achiral–chiral LC–LC method for the analysis of branched‐chain amino acids in commercial tablets. ELECTROPHORESIS. https://doi.org/10.1002/elps.202300278

Vancouver

Varfaj I, Abualzulof GWA, Moretti S, Migni A, Uda I, Goracci L, et al. Development of an easy‐to‐set‐up multiple heart‐cutting achiral–chiral LC–LC method for the analysis of branched‐chain amino acids in commercial tablets. ELECTROPHORESIS. 2024. doi:10.1002/elps.202300278

BibTeX
@article{Varfaj2024,
  author = {Varfaj, Ina and Abualzulof, Ghaid W A and Moretti, Simone and Migni, Anna and Uda, Irene and Goracci, Laura and Ianni, Federica and Carotti, Andrea and Sardella, Roccaldo},
  title = {Development of an easy‐to‐set‐up multiple heart‐cutting achiral–chiral LC–LC method for the analysis of branched‐chain amino acids in commercial tablets},
  journal = {ELECTROPHORESIS},
  year = {2024},
  doi = {10.1002/elps.202300278}
}
Kostenlos starten →