EUVIMEDEUVIMED entdecken
Crossref

Quality by design‐based capillary electrophoresis method development for the quantitative analysis of four iridoid compounds in Gentiana macrophylla Radix

Zhiyong Zhang, Xiaoyang Zhang, Shunan Li, Yun Chen, Zheng Li, Yunlan Lian, Wenlong Li iD

ELECTROPHORESIS · 2023

DOI: 10.1002/elps.202200267 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ELECTROPHORESIS, 2023. Verfasst von Zhiyong Zhang und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China. Hauptthemen laut MEDLINE: Gentiana, Drugs, Chinese Herbal. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Wuhan Science and Technology Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, the capillary electrophoresis‐photodiode array detector was employed for the analysis of four iridoid compounds in Gentiana macrophylla Radix (RGM), and the method was optimized based on the concept of analytical quality by design (AQbD). The peak areas relative standard deviation ( n = 3) and resolution of the four analytes were selected as critical method attributes. Fractional factorial design test combined with Pareto analysis were employed to screen critical method parameters (buffer concentration, pH, sodium dodecyl sulfate [SDS] micelle concentration, temperature, and voltage). Subsequently, three main factors (buffer concentration, buffer pH, and SDS concentration) were selected by central composite design test for constructing the design space. The optimal separation conditions as follows: capillary column (50.2 cm × 50 µm, detection length 40 cm). Working background electrolyte consisted of 51 mmol/L borax solution (pH = 9.47) and 40 mmol/L SDS. The samples were injected by pressure (5 s at 0.5 psi) and the detection was performed at 254 nm. Applied voltage was 20 kV and column temperature was 23°C. The developed method is rapid and reliable for the quantitative analysis of four iridoid compounds in RGM, providing a reference for the application of AQbD concept in the analysis of natural products.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GentianaDrugs, Chinese HerbalIridoidsElectrophoresis, CapillaryPlant Roots

Stichwörter der Autor:innen

Gentiana macrophylla Radixanalytical quality by designcapillary electrophoresiscentral composite designfractional factorial design

Substanzen

IridoidsDrugs, Chinese Herbal

Autor:innen und Institutionen

  • College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China.
  • State Key Laboratory of Component-Based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China.
  • Haihe Laboratory of Modern Chinese Medicine, Tianjin, P. R. China.
  • Shanxi Institute for Food and Drug Control, Taiyuan, Shanxi, P. R. China.

ORCID-Profile: Wenlong Li

Förderung

  • Wuhan Science and Technology Project

Zitieren

APA

Zhang, Z., Zhang, X., Li, S., Chen, Y., Li, Z., Lian, Y., & Li, W. (2023). Quality by design‐based capillary electrophoresis method development for the quantitative analysis of four iridoid compounds in Gentiana macrophylla Radix. ELECTROPHORESIS. https://doi.org/10.1002/elps.202200267

Vancouver

Zhang Z, Zhang X, Li S, Chen Y, Li Z, Lian Y, et al. Quality by design‐based capillary electrophoresis method development for the quantitative analysis of four iridoid compounds in Gentiana macrophylla Radix. ELECTROPHORESIS. 2023. doi:10.1002/elps.202200267

BibTeX
@article{Zhang2023,
  author = {Zhang, Zhiyong and Zhang, Xiaoyang and Li, Shunan and Chen, Yun and Li, Zheng and Lian, Yunlan and Li, Wenlong},
  title = {Quality by design‐based capillary electrophoresis method development for the quantitative analysis of four iridoid compounds in Gentiana macrophylla Radix},
  journal = {ELECTROPHORESIS},
  year = {2023},
  doi = {10.1002/elps.202200267}
}
Kostenlos starten →