EUVIMEDEUVIMED entdecken
Crossref

Evolution of the theoretical description of the isoelectric focusing experiment: II. An open system isoelectric focusing experiment is a transient, bidirectional isotachophoretic experiment

Gyula Vigh, Bohuslav Gaš iD

ELECTROPHORESIS · 2023

DOI: 10.1002/elps.202200238 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ELECTROPHORESIS, 2023. Verfasst von Gyula Vigh und 1 weiteren Autor:innen. Beteiligte Einrichtung: Chemistry Department, Texas A&M University, College Station, Texas, USA. Hauptthemen laut MEDLINE: Isotachophoresis. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Grantová Agentura České Republiky, Agilent Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The carrier ampholytes‐based (CA‐based) isoelectric focusing (IEF) experiment evolved from Svensson's closed system IEF (constant spatial current density, absence of convective mixing, counter‐balancing electrophoretic and diffusive fluxes yielding a steady state pH gradient) to the contemporary open system IEF (absence of convective mixing, large cross‐sectional area electrode vessels, lack of counter‐balancing electrophoretic‐ and diffusive fluxes leading to transient pH gradients). Open system IEF currently is described by a two‐stage model: In the first stage, a rapid IEF process forms the pH gradient which, in the second stage, is slowly degraded by isotachophoretic processes that move the most acidic and most basic CAs into the electrode vessels. An analysis of the effective mobilities and the effective mobility to conductivity ratios of the anolyte, catholyte, and the CAs indicates that in open system IEF experiments a single process, transient bidirectional isotachophoresis (tbdITP) operates from the moment current is turned on until it is turned off. In tbdITP, the anolyte and catholyte provide the leading ions and the p I 7 CA or the reactive boundary of the counter‐migrating H 3 O + and OH − ions serves as the shared terminator. The outcome of the tbdITP process is determined by the ionic mobilities, p K a values, and loaded amounts of all ionic and ionizable components: It is constrained by both the transmitted amount of charge and the migration space available for the leading ions. tbdITP and the resulting pH gradient can never reach steady state with respect to the spatial coordinate of the separation channel.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

IsotachophoresisHydrogen-Ion ConcentrationIsoelectric FocusingAmpholyte MixturesElectric Conductivity

Stichwörter der Autor:innen

isoelectric focusingsimulationtransient bidirectional isotachophoresis

Substanzen

Ampholyte Mixtures

Autor:innen und Institutionen

  • Chemistry Department, Texas A&M University, College Station, Texas, USA.
  • Faculty of Science, Charles University, Prague, Czech Republic.

ORCID-Profile: Bohuslav Gaš

Förderung

  • Grantová Agentura České Republiky
  • Agilent Foundation

Zitieren

APA

Vigh, G., & Gaš, B. (2023). Evolution of the theoretical description of the isoelectric focusing experiment: II. An open system isoelectric focusing experiment is a transient, bidirectional isotachophoretic experiment. ELECTROPHORESIS. https://doi.org/10.1002/elps.202200238

Vancouver

Vigh G, Gaš B. Evolution of the theoretical description of the isoelectric focusing experiment: II. An open system isoelectric focusing experiment is a transient, bidirectional isotachophoretic experiment. ELECTROPHORESIS. 2023. doi:10.1002/elps.202200238

BibTeX
@article{Vigh2023,
  author = {Vigh, Gyula and Gaš, Bohuslav},
  title = {Evolution of the theoretical description of the isoelectric focusing experiment: II. An open system isoelectric focusing experiment is a transient, bidirectional isotachophoretic experiment},
  journal = {ELECTROPHORESIS},
  year = {2023},
  doi = {10.1002/elps.202200238}
}
Kostenlos starten →