EUVIMEDEUVIMED entdecken
Crossref

Capacitive Genosensor for SARS‐CoV‐2 RNA Detection

Sinan Akkurt, Yasemin Delen Akçay

Electroanalysis · 2026-11 · 38 (11)

DOI: 10.1002/elan.70258 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electroanalysis, online erschienen am 13.11.2026. Verfasst von Sinan Akkurt und 1 weiteren Autor:innen. Die Arbeit nennt 48 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid and reliable detection of SARS‐CoV‐2 RNA remains essential for effective surveillance and early diagnosis of COVID‐19 infection. In this study, a label‐free electrochemical capacitive genosensor was developed for sensitive detection of SARS‐CoV‐2 RNA using a screen‐printed carbon electrode modified with electropolymerized polypyrrole (PPy) and aminophenylboronic acid (APBA). Stable immobilization of the RNA probe was achieved through electrostatic interactions with the conductive polymer matrix and reversible boronate–ribose binding, providing improved probe stability and hybridization efficiency without the need for labeling or amplification steps. Hybridization events were monitored via chronoimpedimetric measurements based on interfacial capacitance changes at the electrode–electrolyte interface. Under optimized conditions in HEPES buffer (50 mM, pH 6.5), the developed genosensor exhibited a rapid response with an optimal hybridization time of approximately 90 s and demonstrated a linear analytical range between 10 and 1000 fM (R 2 = 0.9926 ± 0.0052, n = 5). The limit of detection and limit of quantification were calculated as 3.1 fM and 9.3 fM, respectively, comparable to previously reported amplification‐free electrochemical SARS‐CoV‐2 genosensors. Repeatability studies performed by spiking RNA into serum samples showed minimal matrix interference (~4% deviation from calibration values), with recovery values of 106.2% and 102.1% at 10 and 1000 fM, respectively, confirming satisfactory analytical accuracy. Six biosensors stored at +4 °C or at room temperature in the dark retained 96.9%/91.1% and 87.2%/78.5% of their initial response after 30 and 60 days, respectively, confirming acceptable long‐term stability, more pronounced at +4 °C. These findings demonstrate that the proposed PPy/APBA‐based capacitive genosensor provides a rapid, sensitive, and cost‐effective platform for amplification‐free detection of SARS‐CoV‐2 RNA and represents a promising candidate for point‐of‐care compatible nucleic acid diagnostics.

Zitieren

APA

Akkurt, S., & Akçay, Y. D. (2026). Capacitive Genosensor for SARS‐CoV‐2 RNA Detection. Electroanalysis, 38(11). https://doi.org/10.1002/elan.70258

Vancouver

Akkurt S, Akçay YD. Capacitive Genosensor for SARS‐CoV‐2 RNA Detection. Electroanalysis. 2026;38(11). doi:10.1002/elan.70258

BibTeX
@article{Akkurt2026,
  author = {Akkurt, Sinan and Akçay, Yasemin Delen},
  title = {Capacitive Genosensor for SARS‐CoV‐2 RNA Detection},
  journal = {Electroanalysis},
  year = {2026},
  volume = {38},
  number = {11},
  doi = {10.1002/elan.70258}
}
Kostenlos starten →