EUVIMEDEUVIMED entdecken
Crossref

Simultaneous Electrochemical Detection of Pb (II) and Cu (II) at Reactive Black Dye/MgAl‐Layered Double Hydroxide Modified Electrode

Claudia Mafopa Lontchi, Herve Leclerc Tcheumi, Gustave Kenne Dedzo, Emmanuel Ngameni

Electroanalysis · 2026-06 · 38 (6)

DOI: 10.1002/elan.70178 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electroanalysis, online erschienen am 21.06.2026. Verfasst von Claudia Mafopa Lontchi und 3 weiteren Autor:innen. Die Arbeit nennt 66 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Environmental pollution by heavy metals such as Cu(II) and Pb(II) is recognized as a major public health issue. Considering that these two heavy metals are generally present simultaneously in the same polluted environments, the development of fast, robust, and cost‐effective analytical tools for their simultaneous quantification is of considerable importance. In this study, a composite material (MgAl‐RB5) obtained by the modification of a MgAl‐layered double hydroxide (LDH) by an anionic dye (Reactive Black 5 (RB5)) was synthesized and used as a glassy carbon electrode modifier, applied for the simultaneous electrochemical detection of Pb(II) and Cu(II). The presence of the dye adsorbed onto the LDH (0.23 mmol g −1 ) and the affinity of the hybrid material for cationic compounds were highlighted by physicochemical (FTIR, TGA, BET‐specific surface area, and SEM) and electrochemical characterizations. The electrochemical signals of Cu(II) and Pb(II) at the glassy carbon electrode were improved in the presence of MgAl‐RB5 at the electrode surface due to the accumulation of these metal cations through complexation with the immobilized dye molecules. After optimization of some key experimental parameters (pH of the accumulation solution, deposition potential, nature of electrolytic solution, and accumulation times), limits of detection of 5.2 nM (1.08 µg L −1 ) and 8.1 nM (0.51 µg L −1 ) were obtained for Pb(II) and Cu(II), respectively, in the concentration range 0.1–8 μM. The sensor displayed good efficiency in several tested environmental samples, confirming tested and confirmed its potential use for the simultaneous detection of Cu(II) and Pb(II) in environmental pollution monitoring.

Zitieren

APA

Lontchi, C. M., Tcheumi, H. L., Dedzo, G. K., & Ngameni, E. (2026). Simultaneous Electrochemical Detection of Pb (II) and Cu (II) at Reactive Black Dye/MgAl‐Layered Double Hydroxide Modified Electrode. Electroanalysis, 38(6). https://doi.org/10.1002/elan.70178

Vancouver

Lontchi CM, Tcheumi HL, Dedzo GK, Ngameni E. Simultaneous Electrochemical Detection of Pb (II) and Cu (II) at Reactive Black Dye/MgAl‐Layered Double Hydroxide Modified Electrode. Electroanalysis. 2026;38(6). doi:10.1002/elan.70178

BibTeX
@article{Lontchi2026,
  author = {Lontchi, Claudia Mafopa and Tcheumi, Herve Leclerc and Dedzo, Gustave Kenne and Ngameni, Emmanuel},
  title = {Simultaneous Electrochemical Detection of Pb (II) and Cu (II) at Reactive Black Dye/MgAl‐Layered Double Hydroxide Modified Electrode},
  journal = {Electroanalysis},
  year = {2026},
  volume = {38},
  number = {6},
  doi = {10.1002/elan.70178}
}