EUVIMEDEUVIMED entdecken
Crossref

Surface Characterization of Various Iron Chalcogenide Glass Ion‐Selective Electrode Membranes

Roland De Marco, Maxwell Fenton, Todd R. Martz, Nataliya Tsud, Viacheslav Kalinovych, Anastasiia Deineko, Ivan Khalakhan, Alberto Zirino, Anna Lashtabeg, Noah B. Corbett, Katherine A. Barbeau

Electroanalysis · 2026-05 · 38 (5)

DOI: 10.1002/elan.70165 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electroanalysis, online erschienen am 17.05.2026. Verfasst von Roland De Marco und 10 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Gefördert von: U.S. National Science Foundation, CERIC, Australian Synchrotron.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We have characterized iron chalcogenide glass ion‐selective electrode (ISE) membranes sourced from several different laboratories (viz., two prepared by Nanolytical in the present study, one sourced from Curtin University from two decades ago, and another sourced from the Chemical Sensors Group at St Petersburg University, Russia) using synchrotron radiation X‐ray photoelectron spectroscopy (SR XPS), near‐edge X‐ray absorption fine structure (NEXAFS) spectroscopy and field emission scanning electron microscopy (FESEM). It has been found that the surface speciation and surface composition of membranes are comparable to previously characterized ones within the bounds of experimental uncertainty, confirming the uniformity and integrity of ISE membranes prepared using a similar method. The FESEM morphology of membranes revealed the nanoscale porosity of a 10 nm thick modified surface layer (MSL) on the iron chalcogenide glass ISE, with Fe L3 edge NEXAFS depth profiling of membranes exposed to very low levels of Fe 3+ in buffered media, as well as higher concentrations in unbuffered solutions, revealing that ion‐exchange occurs over the entirety of the ISE membrane MSL. Furthermore, in accordance with observations of an “Fe suctioning” effect in unbuffered and buffered Fe standards at low levels of Fe 3+ , we revealed declines in Fe L3 edge NEXAFS signals in the depth profiles of Fe‐treated membranes compared to a polished ISE membrane. Accordingly, similarly prepared ISE membranes can provide repeatable and internally consistent membrane characteristics.

Förderung

  • U.S. National Science Foundation
  • CERIC
  • Australian Synchrotron

Zitieren

APA

Marco, R. D., Fenton, M., Martz, T. R., Tsud, N., Kalinovych, V., Deineko, A., Khalakhan, I., Zirino, A., Lashtabeg, A., Corbett, N. B., & Barbeau, K. A. (2026). Surface Characterization of Various Iron Chalcogenide Glass Ion‐Selective Electrode Membranes. Electroanalysis, 38(5). https://doi.org/10.1002/elan.70165

Vancouver

Marco RD, Fenton M, Martz TR, Tsud N, Kalinovych V, Deineko A, et al. Surface Characterization of Various Iron Chalcogenide Glass Ion‐Selective Electrode Membranes. Electroanalysis. 2026;38(5). doi:10.1002/elan.70165

BibTeX
@article{Marco2026,
  author = {Marco, Roland De and Fenton, Maxwell and Martz, Todd R. and Tsud, Nataliya and Kalinovych, Viacheslav and Deineko, Anastasiia and Khalakhan, Ivan and Zirino, Alberto and Lashtabeg, Anna and Corbett, Noah B. and Barbeau, Katherine A.},
  title = {Surface Characterization of Various Iron Chalcogenide Glass Ion‐Selective Electrode Membranes},
  journal = {Electroanalysis},
  year = {2026},
  volume = {38},
  number = {5},
  doi = {10.1002/elan.70165}
}
Kostenlos starten →