EUVIMEDEUVIMED entdecken
Crossref

Eco‐Friendly Voltammetric Quantification of Paroxetine Using a Graphene–Copper Oxide Nanohybrid‐Based Electrode

Dina A. Mohamed, Amir Shaaban Farag, Maha M. Abou El‐Alamin, Elmorsy Khaled, Abdellatef A. Radowan

Electroanalysis · 2026-03 · 38 (3)

DOI: 10.1002/elan.70124 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electroanalysis, online erschienen am 22.03.2026. Verfasst von Dina A. Mohamed und 4 weiteren Autor:innen. Die Arbeit nennt 80 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study reports the design, fabrication, and characterization of a novel carbon paste electrode integrated with graphene and copper oxide nanohybrid (Gr/CuONPs/CPE) for the sensitive and selective voltammetric determination of the serotonin reuptake inhibitor paroxetine (PAR). Modification of the electrode surface with Gr/CuONPs nanohybrid facilitated a more efficient electrochemical oxidation of PAR at 1.046 V in BR buffer (pH 6) based on the synergistic electrocatalytic effect of the nanohybrid components and the enhanced electroactive surface area provided by the nanostructure. The electroanalytical investigations combined with molecular orbital calculations revealed a diffusion‐controlled mechanism through oxidation of the pyrimidine nitrogen atom (N6), accompanied with the transfer of two protons/one electron. At the optimized Gr/CuONPs ratio within the nanohybrid, the cited electrode demonstrated a linear response within the PAR concentrations ranged from 0.066 to 4.939 µg mL −1 and an limit of detection value of 45.4 ng mL −1 . The Gr/CuONPs/CPE exhibited extended storage stability with excellent fabrication and electrochemical measurement reproducibility. Based on the environmental impact of PAR, the developed voltammetric procedure was effectively applied for monitoring of PAR residues in surface water samples and marketed formulations with acceptable recoveries. The green analytical metrics (Analytical Eco‐Scale and Analytical GrEEness metric approach) were evaluated, highlighting the method's environmental friendliness of the suggested voltammetric procedures.

Zitieren

APA

Mohamed, D. A., Farag, A. S., El‐Alamin, M. M. A., Khaled, E., & Radowan, A. A. (2026). Eco‐Friendly Voltammetric Quantification of Paroxetine Using a Graphene–Copper Oxide Nanohybrid‐Based Electrode. Electroanalysis, 38(3). https://doi.org/10.1002/elan.70124

Vancouver

Mohamed DA, Farag AS, El‐Alamin MMA, Khaled E, Radowan AA. Eco‐Friendly Voltammetric Quantification of Paroxetine Using a Graphene–Copper Oxide Nanohybrid‐Based Electrode. Electroanalysis. 2026;38(3). doi:10.1002/elan.70124

BibTeX
@article{Mohamed2026,
  author = {Mohamed, Dina A. and Farag, Amir Shaaban and El‐Alamin, Maha M. Abou and Khaled, Elmorsy and Radowan, Abdellatef A.},
  title = {Eco‐Friendly Voltammetric Quantification of Paroxetine Using a Graphene–Copper Oxide Nanohybrid‐Based Electrode},
  journal = {Electroanalysis},
  year = {2026},
  volume = {38},
  number = {3},
  doi = {10.1002/elan.70124}
}
Kostenlos starten →