EUVIMEDEUVIMED entdecken
Open Access

Determination of Mercury with a Miniature Sensor for Point‐of‐care Testing

Caterina Andreasi Bassi, Zhizhen Wu, Linda Forst, Ian Papautsky

Electroanalysis · 2023-03 · 35 (3)

DOI: 10.1002/elan.202200234 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electroanalysis, online erschienen am 18.08.2022. Verfasst von Caterina Andreasi Bassi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, University of Illinois Chicago, IL, 851 S. Morgan Street, 218 SEO, Chicago, IL 60607, USA. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIEHS NIH HHS, NIOSH CDC HHS, National Institute for Occupational Safety and Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In developing countries, subsistence gold mining entails mixing metallic mercury with crushed sediments to extract gold. In this approach, the gold−mercury amalgam is heated to evaporate mercury and obtain gold. Thus, the highly volatile mercury can be absorbed through inhalation, resulting in adverse health effects. Urinalysis can be used to detect mercury, which is excreted in urine and feces, and correlate exposure with toxic effects. The current gold standard analytical methods are based on fluorescence or inductively coupled plasma mass spectrometry methods, but are expensive, time consuming, and are not easily accessible in countries where testing is needed. In this work, we report on a miniature electrochemical sensor that can rapidly detect mercury in urine at levels well below the US Biological Exposure Index (BEI) limit of 50 ppb (μg/L). The sensor is based on a thin‐film gold electrode and anodic stripping voltammetry electroanalytical approach. The sensor successfully detected mercury at trace levels in urine, with a limit of detection of ∼15 ppb Hg in the linear range of 20–80 ppb. With the low‐cost disposable sensors and portable instrumentation, it is well suited for point‐of‐care applications.

Schlagwörter

Stichwörter der Autor:innen

Electrochemical sensoranodic stripping voltammetrymercury determinationpoint-of-carethin film gold sensorurine

Autor:innen und Institutionen

  • Department of Biomedical Engineering, University of Illinois Chicago, IL, 851 S. Morgan Street, 218 SEO, Chicago, IL 60607, USA.
  • Department of Public Health, University of Illinois Chicago, IL, Chicago, IL 60607, USA.

Förderung

  • NIEHS NIH HHS
  • NIOSH CDC HHS
  • National Institute for Occupational Safety and Health

Zitieren

APA

Bassi, C. A., Wu, Z., Forst, L., & Papautsky, I. (2023). Determination of Mercury with a Miniature Sensor for Point‐of‐care Testing. Electroanalysis, 35(3). https://doi.org/10.1002/elan.202200234

Vancouver

Bassi CA, Wu Z, Forst L, Papautsky I. Determination of Mercury with a Miniature Sensor for Point‐of‐care Testing. Electroanalysis. 2023;35(3). doi:10.1002/elan.202200234

BibTeX
@article{Bassi2023,
  author = {Bassi, Caterina Andreasi and Wu, Zhizhen and Forst, Linda and Papautsky, Ian},
  title = {Determination of Mercury with a Miniature Sensor for Point‐of‐care Testing},
  journal = {Electroanalysis},
  year = {2023},
  volume = {35},
  number = {3},
  doi = {10.1002/elan.202200234}
}
Kostenlos starten →