EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY-NC-ND 4.0

HRV‐Based Thresholds in Rowing: Validity and Reliability Assessment

Steffen Held iD, Ludwig Rappelt iD, Tim Wiedenmann, Julius Rommelmann, Thomas Gronwald iD, Lars Donath iD

European Journal of Sport Science · 2025

DOI: 10.1002/ejsc.70054 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift European Journal of Sport Science, 2025. Verfasst von Steffen Held und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sport and Management, IST University of Applied Sciences, Duesseldorf, Germany. Hauptthemen laut MEDLINE: Heart Rate, Water Sports, Anaerobic Threshold. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The concurrent validity of lactate thresholds (LT1, LT2) and between‐day reliability data from the rowing‐specific heart rate variability (HRV)‐based thresholds (HRVT) were examined. Thus, 21 rowers (19.6 ± 2.8 years; 1.78 ± 0.09 m; 72.8 ± 11.3 kg) performed two rowing ergometer step tests (starting 100–150 W; 40–50 W increment/4 min) one week apart. Thirteen participants completed both sessions and were included in the reliability analysis. Reliability of power at first (HRVT1) and second HRVT (HRVT2) revealed low standard error of measurements (SEM: HRVT1 = 12 W; HRVT2 = 6 W), coefficient of variation (CV: HRVT1 = 11.5%; HRVT2 = 5.9%), and good to excellent intraclass coefficient (ICC: HRVT1 = 0.83; HRVT2 = 0.93). HRVT2 revealed a sufficient level of agreement (LoA = 35 W) and practicable low minimal detectable changes (MDC = 16 W). In contrast, LoA (46 W) and MDC (32 W) were notably higher for HRVT1. Furthermore, concurrent validity data showed good to excellent ICC values (0.90), low SEM (7 W) and sufficient LoA (35 W) between HRVT2 and power at LT2. Despite good ICC values (0.78), the SEM (LT1 = 12 W) and LoA (41 W) data were notably higher during HRVT1 versus power at LT1 comparison. Thus, HRVT might be a promising, valid, and reliable option to estimate LT in rowing, with HRVT2 having particularly favorable properties as a surrogate for LT2.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart RateWater SportsAnaerobic ThresholdHumansReproducibility of ResultsYoung AdultMaleExercise TestLactic AcidFemaleAdultAdolescent

Stichwörter der Autor:innen

cardiorespiratory fitnessexercise monitoringperformance metricsphysiological testingpower output

Substanzen

Lactic Acid

Autor:innen und Institutionen

  • Department of Sport and Management, IST University of Applied Sciences, Duesseldorf, Germany.
  • Department of Intervention Research in Exercise Training, German Sport University Cologne, Cologne, Germany.
  • Department of Movement and Training Science, University of Wuppertal, Wuppertal, Germany.
  • Institute of Interdisciplinary Exercise Science and Sports Medicine, MSH Medical School Hamburg, Hamburg, Germany.

ORCID-Profile: Steffen Held, Ludwig Rappelt, Thomas Gronwald, Lars Donath

Zitieren

APA

Held, S., Rappelt, L., Wiedenmann, T., Rommelmann, J., Gronwald, T., & Donath, L. (2025). HRV‐Based Thresholds in Rowing: Validity and Reliability Assessment. European Journal of Sport Science. https://doi.org/10.1002/ejsc.70054

Vancouver

Held S, Rappelt L, Wiedenmann T, Rommelmann J, Gronwald T, Donath L. HRV‐Based Thresholds in Rowing: Validity and Reliability Assessment. European Journal of Sport Science. 2025. doi:10.1002/ejsc.70054

BibTeX
@article{Held2025,
  author = {Held, Steffen and Rappelt, Ludwig and Wiedenmann, Tim and Rommelmann, Julius and Gronwald, Thomas and Donath, Lars},
  title = {HRV‐Based Thresholds in Rowing: Validity and Reliability Assessment},
  journal = {European Journal of Sport Science},
  year = {2025},
  doi = {10.1002/ejsc.70054}
}
Kostenlos starten →