Continuous glucose monitoring in para cyclists: An observational study
European Journal of Sport Science · 2024
DOI: 10.1002/ejsc.12220 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift European Journal of Sport Science, 2024. Verfasst von Vera Weijer und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Sport and Exercise, HAN University of Applied Sciences, Nijmegen, the Netherlands. Hauptthemen laut MEDLINE: Bicycling, Blood Glucose, Blood Glucose Self-Monitoring, Hypoglycemia. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nationaal Regieorgaan Praktijkgericht Onderzoek SIA, Province of Gelderland.
Abstract (Originalsprache)
Continuous glucose monitoring (CGM) is an emerging tool for dietary counseling in athletes. This study aimed to explore blood glucose profiles in Para cyclists and evaluate CGM accuracy at rest and during exercise. Thirteen Para cyclists, comprising eight hand bikers and five cyclists, wore a CGM sensor (Abbott) for 2 weeks. Participants recorded the timing of meals and regular training sessions and executed one standardized training session. Fifteen capillary blood glucose reference values (seven at rest and eight during the standardized training) were obtained by finger pricks. Mean glucose concentrations and time spent in hypoglycemia (7.8 mmol/L) were calculated over 24 hrs and during daytime, nighttime, exercise, and 2 hrs postprandial periods. Mean absolute relative differences (MARD) were calculated between the CGM and capillary blood glucose. The mean glucose concentration over the 24 hr‐period was 5.7 (5.6–5.8) mmol/L. Athletes were in the euglycemia range 91% of the time. Hyperglycemia was almost exclusively observed postprandially and during exercise. Hypoglycemia was restricted to the night and was particularly observed in athletes with a spinal cord injury. CGM accuracy was acceptable at rest (MARD: 12%) but markedly lower during exercise (MARD: 34%; p = 0.01), especially for hand bikers (MARD: 41%) compared with cyclists (MARD: 24%; p = 0.01). Para cyclists generally do not display signs of disturbed glucose regulation. However, the increased risk for nocturnal hypoglycemia in athletes with a spinal cord injury warrants attention. Furthermore, CGM accuracy is compromised during exercise, especially if the sensor is in proximity to highly active muscles.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Sport and Exercise, HAN University of Applied Sciences, Nijmegen, the Netherlands.
- Department of Human Biology, NUTRIM, Maastricht University Medical Centre+, Maastricht, the Netherlands.
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK.
ORCID-Profile: Luc J C van Loon
Förderung
- Nationaal Regieorgaan Praktijkgericht Onderzoek SIA
- Province of Gelderland
Zitieren
APA
Weijer, V., van der Werf, R., van der Haijden, M., Jeukendrup, A., van Loon, L. J. C., & Dijk, J. V. (2024). Continuous glucose monitoring in para cyclists: An observational study. European Journal of Sport Science. https://doi.org/10.1002/ejsc.12220
Vancouver
Weijer V, van der Werf R, van der Haijden M, Jeukendrup A, van Loon LJC, Dijk JV. Continuous glucose monitoring in para cyclists: An observational study. European Journal of Sport Science. 2024. doi:10.1002/ejsc.12220
BibTeX
@article{Weijer2024,
author = {Weijer, Vera and van der Werf, Rob and van der Haijden, Myrthe and Jeukendrup, Asker and van Loon, Luc J C and Dijk, Jan-Willem van},
title = {Continuous glucose monitoring in para cyclists: An observational study},
journal = {European Journal of Sport Science},
year = {2024},
doi = {10.1002/ejsc.12220}
}
EUVIMED