Accuracy of a non‐exercise method using seismocardiography for the estimation of V̇O 2 peak in sub‐elite football players
European Journal of Sport Science · 2024
DOI: 10.1002/ejsc.12147 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Sport Science, 2024. Verfasst von Mikkel Thunestvedt Hansen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Xlab, Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark. Hauptthemen laut MEDLINE: Exercise Test, Soccer, Oxygen Consumption. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: VentriJect Aps, Denmark, The Center for Healthy Aging, University of Copenhagen.
Abstract (Originalsprache)
A non‐exercise method equation using seismocardiography for estimating V̇O 2 peak (SCG V̇O 2 peak) has previously been validated in healthy subjects. However, the performance of the SCG V̇O 2 peak within a trained population is unknown, and the ability of the model to detect changes over time is not well elucidated. Forty‐seven sub‐elite football players were tested at the start of pre‐season (SPS) and 36 players completed a test after eight weeks at the end of the pre‐season (EPS). Testing included an SCG V̇O 2 peak estimation at rest and a graded cardiopulmonary exercise test (CPET) on a treadmill for determination of V̇O 2 peak. Agreement between SCG V̇O 2 peak and CPET V̇O 2 peak showed a large underestimation at SPS (bias ± 95% CI: −9.9 ± 1.8, 95% Limits of Agreement: 2.2 to −22.0 mL·min −1 kg −1 ). At EPS no interaction ( p = 0.3590) but a main effect of time ( p < 0.0001) and methods ( p < 0.0001) was observed between SCG and CPET V̇O 2 peak. No correlation in V̇O 2 peak changes was observed between SCG and CPET ( r = −20.0, p = 0.2484) but a fair agreement in classifying the correct directional change in V̇O 2 peak with the SCG method was found (Cohen's κ coefficient = 0.28 ± 0.25). Overall, the SCG V̇O 2 peak method lacks accuracy and despite being able to estimate group changes, it was incapable of detecting individual changes in V̇O 2 peak following a pre‐season period in sub‐elite football players. The SCG algorithm needs to be further adjusted and the accuracy and precision improved for the method to be applicable for use within a trained population.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Xlab, Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
- Department of Geriatrics, Bispebjerg University Hospital, Copenhagen, Denmark.
- Department of Human Physiology and Biochemistry, Riga Stradiņš University, Riga, Latvia.
ORCID-Profile: Mikkel Thunestvedt Hansen
Förderung
- VentriJect Aps, Denmark
- The Center for Healthy Aging, University of Copenhagen
Zitieren
APA
Hansen, M. T., Rømer, T., Lange, K. K., Dela, F., & Helge, J. W. (2024). Accuracy of a non‐exercise method using seismocardiography for the estimation of V̇O 2 peak in sub‐elite football players. European Journal of Sport Science. https://doi.org/10.1002/ejsc.12147
Vancouver
Hansen MT, Rømer T, Lange KK, Dela F, Helge JW. Accuracy of a non‐exercise method using seismocardiography for the estimation of V̇O 2 peak in sub‐elite football players. European Journal of Sport Science. 2024. doi:10.1002/ejsc.12147
BibTeX
@article{Hansen2024,
author = {Hansen, Mikkel Thunestvedt and Rømer, Tue and Lange, Kristine Kjær and Dela, Flemming and Helge, Jørn Wulff},
title = {Accuracy of a non‐exercise method using seismocardiography for the estimation of V̇O 2 peak in sub‐elite football players},
journal = {European Journal of Sport Science},
year = {2024},
doi = {10.1002/ejsc.12147}
}
EUVIMED