Assessment of Mechanical Detection Thresholds in Healthy Participants and Patients With Neuropathy: A Comparison of OptiHair2 and Aesthesiometer II
European Journal of Pain · 2025
DOI: 10.1002/ejp.70078 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift European Journal of Pain, 2025. Verfasst von Jan D Wandrey und 7 weiteren Autor:innen. Beteiligte Einrichtung: Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Anaesthesiology …. Hauptthemen laut MEDLINE: Neuralgia, Pain Threshold, Sensory Thresholds, Pain Measurement. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Mechanical detection thresholds (MDTs) are used to assess somatosensory function but can only be evaluated considering the individual sex, age and tested body region. The German Research Network on Neuropathic Pain (DFNS) provides reference values for OptiHair2, a sensitive and expensive glass filament, while nylon filaments such as the Aesthesiometer II are more durable and affordable. In this study, we compare both devices regarding their use for MDT assessment in a variety of participants, thus intending to achieve a higher range for MDT.
Methods
MDTs of healthy children (< 18y), healthy adults (> 18y) and adult patients with symptoms of suspected polyneuropathy were determined using OptiHair2 glass filaments (0.25‐512mN) and Aesthesiometer II nylon filaments (0.63–235.36mN), using the method of limits according to the DFNS protocol. Testing was performed on the cheek, hand and foot in healthy participants; patients were tested on the hand and foot only. Concordance Correlation Coefficient (CCC), Pearson correlation and linear regression analysis were performed.
Results
The study included 55 participants (33 female, 30 healthy adults aged 22–62 years, 10 healthy children aged 9–15 years, 15 patients aged 35–86 years). There was a relevant concordance of MDTs between Aesthesiometer II and OptiHair2 at the hand (CCC children = 0.14, healthy adults = 0.56, patients = 0.66) and foot (CCC children = 0.24, healthy adults = 0.66, patients = 0.70) but not on the cheek (CCC children = 0.00, healthy adults = 0.01).
Conclusions
The Aesthesiometer II can be a viable replacement for OptiHair2 in less densely innervated areas like the feet, when screening for polyneuropathy, especially in bedside settings due to its robust materials. However, its stronger lowest force (0.63 vs. 0.25 mN) implicates poorer sensitivity for MDT assessments when testing highly innervated areas like the face. Significance Statement This study suggests the use of robust Aesthesiometer II nylon filaments as an alternative to the more fragile OptiHair2 glass filaments for MDT assessments. While we find that only OptiHair2 seems to be suitable for more densely innervated areas like the face, Aesthesiometer II's durability and cost‐efficiency make it a useful bedside tool, especially for assessing suspected polyneuropathy in less densely innervated areas like the feet.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Anaesthesiology and Intensive Care, Campus Charité Mitte and Campus Virchow-Klinikum,…
- Berlin Institute of Health at Charité - Universitätsmedizin Berlin, BIH Biomedical Innovation Academy, BIH Charité Digital Clinician Scientist Program, Berlin, Germany.
- Department of Clinical and Biomedical Sciences, Faculty of Health and Life Sciences, University of Exeter, Exeter, UK.
- University Hospital of Pediatrics and Adolescent Medicine, Ruhr-University Bochum, Bochum, Germany.
- Department of Pain Medicine, BG University Hospital Bergmannsheil, Ruhr-University Bochum, Bochum, Germany.
- Department of Neurology, BG University Hospital Bergmannsheil, Ruhr-University Bochum, Bochum, Germany.
ORCID-Profile: Jan D Wandrey, Jan Vollert
Zitieren
APA
Wandrey, J. D., Reinecke, A., Westermann, A., Lücke, T., Enax-Krumova, E., Maier, C., Vollert, J., & Eitner, L. (2025). Assessment of Mechanical Detection Thresholds in Healthy Participants and Patients With Neuropathy: A Comparison of OptiHair2 and Aesthesiometer II. European Journal of Pain. https://doi.org/10.1002/ejp.70078
Vancouver
Wandrey JD, Reinecke A, Westermann A, Lücke T, Enax-Krumova E, Maier C, et al. Assessment of Mechanical Detection Thresholds in Healthy Participants and Patients With Neuropathy: A Comparison of OptiHair2 and Aesthesiometer II. European Journal of Pain. 2025. doi:10.1002/ejp.70078
BibTeX
@article{Wandrey2025,
author = {Wandrey, Jan D and Reinecke, Annika and Westermann, Andrea and Lücke, Thomas and Enax-Krumova, Elena and Maier, Christoph and Vollert, Jan and Eitner, Lynn},
title = {Assessment of Mechanical Detection Thresholds in Healthy Participants and Patients With Neuropathy: A Comparison of OptiHair2 and Aesthesiometer II},
journal = {European Journal of Pain},
year = {2025},
doi = {10.1002/ejp.70078}
}
EUVIMED