EUVIMEDEUVIMED entdecken
Crossref

Radiometal‐Based PET Imaging: Coordination Chemistry as a Determinant of In Vivo Performance

Xiaoguang Liu, Wenbo Liu, Min Lai, Baolu Cui, Fanshun Shi, Chuanchuan He, Xiaojuan Zhang, Jianguo Xu, Helin Lu, Qing Cheng, Kai Li

European Journal of Inorganic Chemistry · 20.05.2026 · 29 (15)

DOI: 10.1002/ejic.202600004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Inorganic Chemistry, online erschienen am 27.03.2026. Verfasst von Xiaoguang Liu und 10 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 111 Literaturangaben. Gefördert von: Jiangxi Province Natural Science Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Radiometal‐based positron emission tomography (PET) has become an indispensable tool for molecular imaging, enabling the noninvasive interrogation of biological processes across a broad range of time scales. Despite substantial advances in radionuclide production and targeting vector design, the in vivo performance and quantitative reliability of many radiometal PET tracers remain limited. These shortcomings are frequently attributed to biological factors; however, growing evidence indicates that they originate predominantly from unresolved challenges in coordination chemistry. This review critically examines commonly used PET radiometals, including [ 44 Sc]Sc, [ 64 Cu]Cu, [ 68 Ga]Ga, and [ 89 Zr]Zr, with a particular focus on the role of bifunctional chelating agents in governing metal stability, biodistribution, and imaging fidelity. Rather than providing a catalog of radionuclides and ligands, we identify recurring, cross‐system chemical constraints—such as incomplete metal coordination, insufficient kinetic inertness, and reliance on empirically inherited chelation frameworks—that continue to define the practical limits of radiometal PET. By comparing these systems across different biological time scales, this review highlights how chelator design, more than radionuclide physics alone, dictates translational success. Collectively, these insights underscore the need for mechanistically informed chelator development and standardized evaluation strategies to enable the next generation of robust, quantitative radiometal‐based PET imaging agents.

Förderung

  • Jiangxi Province Natural Science Foundation

Zitieren

APA

Liu, X., Liu, W., Lai, M., Cui, B., Shi, F., He, C., Zhang, X., Xu, J., Lu, H., Cheng, Q., & Li, K. (2026). Radiometal‐Based PET Imaging: Coordination Chemistry as a Determinant of In Vivo Performance. European Journal of Inorganic Chemistry, 29(15). https://doi.org/10.1002/ejic.202600004

Vancouver

Liu X, Liu W, Lai M, Cui B, Shi F, He C, et al. Radiometal‐Based PET Imaging: Coordination Chemistry as a Determinant of In Vivo Performance. European Journal of Inorganic Chemistry. 2026;29(15). doi:10.1002/ejic.202600004

BibTeX
@article{Liu2026,
  author = {Liu, Xiaoguang and Liu, Wenbo and Lai, Min and Cui, Baolu and Shi, Fanshun and He, Chuanchuan and Zhang, Xiaojuan and Xu, Jianguo and Lu, Helin and Cheng, Qing and Li, Kai},
  title = {Radiometal‐Based PET Imaging: Coordination Chemistry as a Determinant of In Vivo Performance},
  journal = {European Journal of Inorganic Chemistry},
  year = {2026},
  volume = {29},
  number = {15},
  doi = {10.1002/ejic.202600004}
}
Kostenlos starten →