EUVIMEDEUVIMED entdecken
Multizentrische StudieBeobachtungsstudieOpen Access · CC BY 4.0

Artificial Intelligence Fully Automated Analysis of Handheld Echocardiography in Real-World Patients with Suspected Heart Failure

Künstliche Intelligenz zur vollautomatisierten Analyse von Handheld-Echokardiographie bei Patient:innen mit Verdacht auf Herzinsuffizienz

Ross T Campbell iD, Mark C Petrie, Kieran F Docherty iD, Katriona J M Brooksbank, Gemma McKinley, Caroline Haig, Alex McConnachie, Carolyn S P Lam, Carly Adamson, Elaine Butler, James P Curtain, Nick Hartshorne-Evans und 21 weitere

European Journal of Heart Failure · 01.12.2025 · 27 (12) · 3401-3410

DOI: 10.1002/ejhf.3783 ↗

Auf einen Blick

Bei 867 Patient:innen mit Verdacht auf Herzinsuffizienz zeigte die KI-Analyse von Handheld-Echokardiographien eine gute diagnostische Genauigkeit für LVEF ≤40 %.

Fragestellung

Wie genau ist die vollautomatisierte KI-Analyse von Handheld-Echokardiographien zum Nachweis einer LVEF ≤40 %, und ist sie mit der Expert:innenanalyse von Kart-Echokardiographien austauschbar?

Methode

Multizentrische, prospektive, beobachtende Studie mit 2 Echokardiographien pro Patient:in; Vergleich von vollautomatisierter KI-Analyse und humaner Expertenanalyse.

Ergebnisse

Bei 867 Patient:innen lieferte die KI auf Handheld-Geräten in 61 % der Scans eine LVEF; bei Kart-Scans in 77 %. Die diagnostische Genauigkeit für LVEF ≤40 % betrug 0,93 (95 %-KI 0,90–0,95). IEC −0,40 (95 %-KI −0,60 bis −0,16).

Schlussfolgerung der Autor:innen

Die KI-automatisierte Analyse von Handheld-Echokardiographie hatte eine gute diagnostische Genauigkeit für den Nachweis von LVEF ≤40 %. Die KI-Analyse der Handheld-Scans war mit der kartbasierten Expertenanalyse austauschbar.

Kernaussagen

  • Diagnostische Genauigkeit für LVEF ≤40 %: 0,93 (95 %-KI 0,90–0,95)
  • KI lieferte auf Handheld-Scans seltener eine LVEF als auf Kart-Scans
  • Handheld-KI und kartbasierte Expertenanalyse waren austauschbar

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Multizentrische Studie in der Zeitschrift European Journal of Heart Failure, online erschienen am 24.07.2025. Verfasst von Ross T Campbell und 32 weiteren Autor:innen. Beteiligte Einrichtung: School of Cardiovascular and Metabolic Health, University of Glasgow, Glasgow, UK. Hauptthemen laut MEDLINE: Heart Failure, Artificial Intelligence, Echocardiography, Stroke Volume. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: AstraZeneca, Roche Diagnostics, British Heart Foundation.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Echocardiography is a rate-limiting step in the timely diagnosis of heart failure (HF). Automated reporting of echocardiograms has the potential to streamline workflow. The aim of this study was to test the diagnostic accuracy of fully automated artificial intelligence (AI) analysis of images acquired using handheld echocardiography and its interchangeability with expert human-analysed cart-based echocardiograms in a real-world cohort with suspected HF. Methods and results In this multicentre, prospective, observational study, patients with suspected HF had two echocardiograms: one handheld portable and one cart-based scan. Both echocardiograms were analysed using fully automated AI software and by human expert sonographers. The primary endpoint was the diagnostic accuracy of AI-automated analysis of handheld echocardiography to detect left ventricular ejection fraction (LVEF) ≤40%. Other endpoints included the interchangeability (assessed using individual equivalence coefficient [IEC]), between AI-automated and human analysis of cart-based LVEF. A total of 867 patients participated. The AI-automated analysis produced an LVEF in 61% of the handheld scans and 77% of the cart-based scans, compared to 76% and 77% of human analyses of the handheld and cart-based scans, respectively. The AI-automated analysis of handheld echocardiography had a diagnostic accuracy of 0.93 (95% confidence interval [CI] 0.90, 0.95) for identifying LVEF ≤40% (compared to the human analysis of cart-based transthoracic echocardiography scans). AI-automated analysis of LVEF on handheld devices was interchangeable with cart-based LVEF reported by two expert humans (IEC −0.40, 95% CI −0.60, −0.16).

Conclusions

Artificial intelligence-automated analysis of handheld echocardiography had good diagnostic accuracy for detecting LVEF ≤40%. AI-automated analysis of LVEF of handheld scans was interchangeable with cart-based expert human analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart FailureArtificial IntelligenceEchocardiographyStroke VolumeVentricular Function, LeftHumansMaleFemaleProspective StudiesAgedMiddle Aged

Stichwörter der Autor:innen

Artificial intelligenceDiagnosisEchocardiographyHandheldHeart failurePoint of care

Autor:innen und Institutionen

  • School of Cardiovascular and Metabolic Health, University of Glasgow, Glasgow, UK.
  • Robertson Centre for Biostatistics, School of Health and Wellbeing, University of Glasgow, Glasgow, UK.
  • National Heart Centre Singapore and Duke-National University of Singapore, Singapore, Singapore.
  • Pumping Marvellous, Preston, UK.
  • Cardiology Department, Queen Elizabeth University Hospital, Glasgow, UK.
  • Cardiology Department, Forth Valley Royal Hospital, Larbert, UK.

ORCID-Profile: Ross T Campbell, Kieran F Docherty, Matthew M Y Lee, Kenneth Mangion, John J V McMurray, David J Lowe

Förderung

  • AstraZeneca
  • Roche Diagnostics
  • British Heart Foundation

Zitieren

APA

Campbell, R. T., Petrie, M. C., Docherty, K. F., Brooksbank, K. J. M., McKinley, G., Haig, C., McConnachie, A., Lam, C. S. P., Adamson, C., Butler, E., Curtain, J. P., Hartshorne-Evans, N., Graham, F. J., Hainey, H., Jarvie, J., Lee, M. M. Y., Macklin, L., Mangion, K., McCoubrey, A., …, & Lowe, D. J. (2025). Artificial Intelligence Fully Automated Analysis of Handheld Echocardiography in Real-World Patients with Suspected Heart Failure. European Journal of Heart Failure, 27(12), 3401-3410. https://doi.org/10.1002/ejhf.3783

Vancouver

Campbell RT, Petrie MC, Docherty KF, Brooksbank KJM, McKinley G, Haig C, et al. Artificial Intelligence Fully Automated Analysis of Handheld Echocardiography in Real-World Patients with Suspected Heart Failure. European Journal of Heart Failure. 2025;27(12):3401-3410. doi:10.1002/ejhf.3783

BibTeX
@article{Campbell2025,
  author = {Campbell, Ross T and Petrie, Mark C and Docherty, Kieran F and Brooksbank, Katriona J M and McKinley, Gemma and Haig, Caroline and McConnachie, Alex and Lam, Carolyn S P and Adamson, Carly and Butler, Elaine and Curtain, James P and Hartshorne-Evans, Nick and Graham, Fraser J and Hainey, Helen and Jarvie, John and Lee, Matthew M Y and Macklin, Leeanne and Mangion, Kenneth and McCoubrey, Aimee and McDowell, Kirsty and McIntyre, Aileen and Nordin, Sabrina and Osmanska, Joanna and Pellicori, Pierpaolo and Simpson, Joanne and Sonecki, Piotr and Taylor, Karen and Taylor-Sweet, Daniel and Turnbull, Pamela and Welsh, Paul and McMurray, John J V and Murphy, Clare L and Lowe, David J},
  title = {Artificial Intelligence Fully Automated Analysis of Handheld Echocardiography in Real-World Patients with Suspected Heart Failure},
  journal = {European Journal of Heart Failure},
  year = {2025},
  volume = {27},
  number = {12},
  pages = {3401--3410},
  doi = {10.1002/ejhf.3783}
}
Kostenlos starten →