EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Haemodynamic Effects of Intra-Aortic Balloon Pumps Stratified by Baseline Pulmonary Artery Pulsatility Index

George Kalapurakal, Vinh Q Chau iD, Teruhiko Imamura, Sanika Tolia, Chris Sciamanna, Gregory P Macaluso, Anjali Joshi, Jessica Pillarella, Sunil Pauwaa, Muhyaldeen Dia, Tarek Kabbany, James Monaco und 5 weitere

ESC Heart Failure · 2025

DOI: 10.1002/ehf2.15083 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ESC Heart Failure, 2025. Verfasst von George Kalapurakal und 16 weiteren Autor:innen. Beteiligte Einrichtung: Advocate Heart Institute, Advocate Christ Medical Center, Oak Lawn, Illinois, USA. Hauptthemen laut MEDLINE: Intra-Aortic Balloon Pumping, Pulmonary Artery, Hemodynamics, Heart Failure. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Intra-aortic balloon pump (IABP) devices are commonly used in patients with heart failure related cardiogenic shock (HF-CS), including those with out-of-proportion right ventricular (RV) dysfunction. Pulmonary artery pulsatility index (PAPi) is a haemodynamic surrogate for RV performance. We aimed to assess short-term haemodynamic changes in patients with HF-CS following IABP support stratified by baseline PAPi. Methods and results This is a single-centre study of 67 consecutive patients with HF-CS who underwent IABP placement between 2020 and 2022. The primary aim was haemodynamic changes of specific variables on pulmonary artery catheter monitoring over 72 h following IABP placement. Secondary aims were clinically significant changes in diuretic regimens, changes in inotropes or vasopressors at 72 h following IABP, along with clinical outcomes. Prior to IABP placement, 57% of the total cohort (median age 59 years [48, 69], 31% female) had Society of Cardiovascular Angiography and Interventions Stage C HF-CS. Thirty-eight (56%) patients had a PAPi <2.0. Following 72 h of IABP support, the PAPi <2.0 group had an observed significant decrease in central venous pressure (CVP; 20 to 12 mmHg, P < 0.001) and mean pulmonary artery pressure (mPAP; 37.5 to 28.5 mmHg, P = 0.001), and an increase in PAPi (1 to 1.6, P = 0.001). No significant change in cardiac index (CI; 2 to 2.1 L/min/m2, P = 0.31) was observed. The PAPi ≥2.0 group (N = 29) had no observed significant change in CVP (10 to 8 mmHg, P = 0.47), or PAPi (2.6 to 2.8, P = 0.92), but there was a significant improvement in CI (1.9 to 2.5 L/min/m2, P = 0.004) along with reduction in mPA (37 to 29 mmHg, P = 0.03). The PAPi <2.0 group had a significant increase in diuretic requirement (52.6% vs. 20.7%, P = 0.01) and numerically greater addition of inotropes/vasopressors (47.3% vs. 34.4%, P = 0.07) compared with the PAPi ≥2.0 group at 72 h following IABP placement. Significantly more patients in the PAPi ≥2.0 group underwent left ventricular assist device (55.2% vs. 26.3%, P = 0.02), with no overall significant differences observed in escalation to veno-arterial extracorporeal membrane oxygenation, 30-day mortality, renal replacement therapy post-IABP, or rates of heart transplantation.

Conclusions

IABP devices in those with HF-CS and low or abnormal PAPi may provide modest short-term haemodynamic benefits without significant improvement in CI, along with greater need for adjustment in medical therapeutics to achieve haemodynamic optimization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intra-Aortic Balloon PumpingPulmonary ArteryHemodynamicsHeart FailureShock, CardiogenicPulsatile FlowHumansFemaleMaleMiddle AgedAgedRetrospective StudiesFollow-Up Studies

Stichwörter der Autor:innen

Cardiogenic shockHaemodynamicsMechanical circulatory support

Autor:innen und Institutionen

  • Advocate Heart Institute, Advocate Christ Medical Center, Oak Lawn, Illinois, USA.
  • Second Department of Internal Medicine, University of Toyama, Toyama, Japan.

ORCID-Profile: Vinh Q Chau

Zitieren

APA

Kalapurakal, G., Chau, V. Q., Imamura, T., Tolia, S., Sciamanna, C., Macaluso, G. P., Joshi, A., Pillarella, J., Pauwaa, S., Dia, M., Kabbany, T., Monaco, J., Dela Cruz, M., Cotts, W. G., Pappas, P., Tatooles, A. J., & Narang, N. (2025). Haemodynamic Effects of Intra-Aortic Balloon Pumps Stratified by Baseline Pulmonary Artery Pulsatility Index. ESC Heart Failure. https://doi.org/10.1002/ehf2.15083

Vancouver

Kalapurakal G, Chau VQ, Imamura T, Tolia S, Sciamanna C, Macaluso GP, et al. Haemodynamic Effects of Intra-Aortic Balloon Pumps Stratified by Baseline Pulmonary Artery Pulsatility Index. ESC Heart Failure. 2025. doi:10.1002/ehf2.15083

BibTeX
@article{Kalapurakal2025,
  author = {Kalapurakal, George and Chau, Vinh Q and Imamura, Teruhiko and Tolia, Sanika and Sciamanna, Chris and Macaluso, Gregory P and Joshi, Anjali and Pillarella, Jessica and Pauwaa, Sunil and Dia, Muhyaldeen and Kabbany, Tarek and Monaco, James and Dela Cruz, Mark and Cotts, William G and Pappas, Patroklos and Tatooles, Antone J and Narang, Nikhil},
  title = {Haemodynamic Effects of Intra-Aortic Balloon Pumps Stratified by Baseline Pulmonary Artery Pulsatility Index},
  journal = {ESC Heart Failure},
  year = {2025},
  doi = {10.1002/ehf2.15083}
}
Kostenlos starten →