Comprehensive Qualitative Drug Screening in Emergency Toxicology Using an Automated LC–MS n System:Simultaneous Quantification of Relevant Drugs and Metabolites in Blood Plasma
Drug Testing and Analysis · 2025-09 · 17 (9) · 1502-1515
DOI: 10.1002/dta.3855 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Drug Testing and Analysis, online erschienen am 19.01.2025. Verfasst von Selina Hemmer und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Experimental and Clinical Toxicology, Institute of Experimental and Clinical Pharmacology and Toxicology, Center for Molecular Signalin…. Hauptthemen laut MEDLINE: Substance Abuse Detection. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Rapid and comprehensive qualitative and quantitative analytical procedures are crucial in 24/7 emergency toxicology (ET) to support diagnosis and treatment of acute intoxications and to monitor their progression and efficacy of detoxification strategies. This study aimed to develop the simultaneous qualitative and quantitative analysis of 62 drugs, as well as seven active metabolites in human blood plasma using an automated liquid chromatography (LC)‐linear ion trap mass spectrometry (MS) screening system. Sample preparation was conducted by liquid–liquid extraction, and plasma concentrations were determined using an electronically stored 5‐point calibration. Validation was performed according to international guidelines and recommendations for ET including selectivity, carry‐over, accuracy, precision, and matrix effects. Finally, applicability was evaluated using case samples and proficiency tests. The method demonstrated selectivity for all analytes, with no significant carry‐over or matrix effects. Accuracy and precision recommended for ET could be fulfilled for all tested analytes, except for 10 analytes. Patient plasma samples were analyzed and compared with results obtained by reference LC‐tandem MS or gas chromatography‐MS methods. Furthermore, the applicability of the method could be demonstrated. It provides a fast, robust, and reliable blood plasma screening for 69 analytes and an additional quantification of 59 analytes relevant in ET. The use of an electronically stored 5‐point calibration and a simplified “push and print solution” allows for straightforward assessment of blood plasma levels of the analytes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Experimental and Clinical Toxicology, Institute of Experimental and Clinical Pharmacology and Toxicology, Center for Molecular Signaling (PZMS), Saarland University, Homburg, Germany.
ORCID-Profile: Markus R Meyer
Zitieren
APA
Hemmer, S., Ninnig, M., Wagmann, L., Manier, S. K., & Meyer, M. R. (2025). Comprehensive Qualitative Drug Screening in Emergency Toxicology Using an Automated LC–MS n System:Simultaneous Quantification of Relevant Drugs and Metabolites in Blood Plasma. Drug Testing and Analysis, 17(9), 1502-1515. https://doi.org/10.1002/dta.3855
Vancouver
Hemmer S, Ninnig M, Wagmann L, Manier SK, Meyer MR. Comprehensive Qualitative Drug Screening in Emergency Toxicology Using an Automated LC–MS n System:Simultaneous Quantification of Relevant Drugs and Metabolites in Blood Plasma. Drug Testing and Analysis. 2025;17(9):1502-1515. doi:10.1002/dta.3855
BibTeX
@article{Hemmer2025,
author = {Hemmer, Selina and Ninnig, Maximilian and Wagmann, Lea and Manier, Sascha K and Meyer, Markus R},
title = {Comprehensive Qualitative Drug Screening in Emergency Toxicology Using an Automated LC–MS n System:Simultaneous Quantification of Relevant Drugs and Metabolites in Blood Plasma},
journal = {Drug Testing and Analysis},
year = {2025},
volume = {17},
number = {9},
pages = {1502--1515},
doi = {10.1002/dta.3855}
}
EUVIMED